MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.anplas.2022.09.001

Медицинская библиотека · Annales de chirurgie plastique et esthetique · 2022

Surgical management of slightly or non-displaced corporal scaphoid fractures by retrograde percutaneous screw fixation through the anterior trapezium horn: A single-center retrospective French study of 33 patients between January 2015 and January 2019.

Lupon E, De Villeneuve Bargemon J B, Dalmas Y, Gandolfi S, Chaput B, Camuzard O, Mansat P, Delclaux S

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Percutaneous screw fixation has recently gained popularity as an alternative to conservative treatment to avoid prolonged immobilization. The placement of a screw in the central axis of the scaphoid has been shown to be biomechanically superior to its eccentricity. Still, it poses difficulties in performing percutaneous screw fixation via both palmar and dorsal approaches.

OBJECTIVE

We describe a palmar percutaneous screwing of corporal fractures of the scaphoid by a simple palmar transtrapezial approach allowing an optimal centering of the screw.

METHOD: We selected patients operated on by the same surgeon using the palmar transtrapezial approach between January 2015 and January 2019 based on the coding used for these fractures and the operative reports. In addition, pre- and postoperative data were collected from the patient's computer and paper records and by telephone contact with the patients.

RESULTS

Thirty-three patients were included. Percutaneous screw fixation of the scaphoid was performed under locoregional anesthesia in the operating room with one arm in the supine position on the arm table. No hyper-extension of the wrist was performed. The Kirchner guidewire passed through the anterior horn of the trapezium and then into the trapezium-scaphoid joint. A screw replaced it after satisfactory centering in the axis of the scaphoid. Management took place on average within 12 days after the trauma. 75.8% were A2 fractures, according to Herbert's classification. The average operating time was 16.63minutes, and in 91% of the cases, the patient was hospitalized for one day. The variation of the scapholunate angle on the preoperative profile radiographs with the angle defined by the axis of the scaphoid screw and the lunate postoperatively was on average 2.94°. One patient presented nonunion, and four showed an undersized screw with a screw overhang requiring revision surgery.

CONCLUSION

The transtrapezial approach to fixation of acute scaphoid fractures facilitates precise percutaneous screw placement in the central axis of the scaphoid. A study of long-term complications, including the degenerative impact on the scaphotrapezial joint, is needed to assess the safety of passage through the anterior horn of the trapezium.

Для цитирования: Lupon E, De Villeneuve Bargemon J B, Dalmas Y, Gandolfi S, Chaput B, Camuzard O, Mansat P, Delclaux S. Surgical management of slightly or non-displaced corporal scaphoid fractures by retrograde percutaneous screw fixation through the anterior trapezium horn: A single-center retrospective French study of 33 patients between January 2015 and January 2019.. Annales de chirurgie plastique et esthetique. 2022. DOI: 10.1016/j.anplas.2022.09.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.