MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bsd.0b013e31816d655e

Медицинская библиотека · Journal of spinal disorders & techniques · 2008

Feasibility of occipital condyle screw placement for occipitocervical fixation: a cadaveric study and description of a novel technique.

Uribe Juan S, Ramos Edwin, Vale Fernando

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

Occipital-cervical (OC) stabilization using occipital condyle fixation with a polyaxial screw-rod construct is described.

OBJECTIVES

To describe a novel technique and initial radiographic results for posterior OC fixation using the occipital condyles for cranial fixation.

SUMMARY OF BACKGROUND DATA: Stabilization of the OC junction remains a challenge. Owing to the regional anatomy and the poor occipital bone purchase, multiple attachment points to the occipital bone are required to increase construct rigidity. To address these issues, we propose a novel OC fixation technique using polyaxial occipital condyle screws for cranial purchase.

METHODS

The OC junction was exposed posteriorly in silicone-injected cadaver heads. Polyaxial titanium screws (3.5 mm) were inserted bicortically solely into the occipital condyles; C1 lateral masses and C2 pedicles, or transarticularly through C1-C2, followed by fixation to a 3-mm rod. Drilling was guided by anatomic landmarks and fluoroscopy. Computerized tomography scans were obtained. Condylar screw angles and lengths were analyzed with respect to historical morphometric condyle measurements and with respect to neurovascular structures.

RESULTS

The condylar entry point was 4 to 5-mm lateral to the foramen magnum on the axial plane, and 1 to 2-mm rostral to the atlantooccipital joint. The mean angle of medialization was 17 degrees (range: 12 to 22 degrees). In the sagittal plane, the maximal superior screw angulation was 5 degrees. The mean screw length to obtain bicortical purchase was 22 mm (range: 20 to 24 mm). The hypoglossal canal was uninterrupted during its full course. The jugular bulb, carotid, and vertebral arteries were not injured by condyle screw placement. No fractures were identified.

CONCLUSION

Condyle screws can be placed without injury to neurovascular structures. OC junction fixation using polyaxial occipital condyle screws is feasible and can be considered a salvage technique or an alternative where other fixation techniques are not available.

Для цитирования: Uribe Juan S, Ramos Edwin, Vale Fernando. Feasibility of occipital condyle screw placement for occipitocervical fixation: a cadaveric study and description of a novel technique.. Journal of spinal disorders & techniques. 2008. DOI: 10.1097/bsd.0b013e31816d655e.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.