MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/2011.6.spine10809

Медицинская библиотека · Journal of neurosurgery. Spine · 2011

Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion.

Ishikawa Yoshimoto, Kanemura Tokumi, Yoshida Go, Matsumoto Akiyuki, Ito Zenya, Tauchi Ryoji, Muramoto Akio, Ohno Shuichiro, Nishimura Yusuke

СтатьяПеревод в очереди

Аннотация

OBJECT: The aim of this study was to retrospectively evaluate the reliability and accuracy of cervical pedicle screw (CPS) placement using an intraoperative, full-rotation, 3D image (O-arm)-based navigation system and to assess the advantages and disadvantages of the system.

METHODS

The study involved 21 consecutive patients undergoing posterior stabilization surgery of the cervical spine between April and December 2009. The patients, in whom 108 CPSs had been inserted, underwent screw placement based on intraoperative 3D imaging and navigation using the O-arm system. Cervical pedicle screw positions were classified into 4 grades, according to pedicle-wall perforations, by using postoperative CT.

RESULTS

Of the 108 CPSs, 96 (88.9%) were classified as Grade 0 (no perforation), 9 (8.3%) as Grade 1 (perforations < 2 mm, CPS exposed, and < 50% of screw diameter outside the pedicle), and 3 (2.8%) as Grade 2 (perforations between ≥ 2 and < 4 mm, CPS breached the pedicle wall, and > 50% of screw diameter outside the pedicle). No screw was classified as Grade 3 (perforation > 4 mm, complete perforation). No neurovascular complications occurred because of CPS placement.

CONCLUSIONS

The O-arm offers high-resolution 2D or 3D images, facilitates accurate and safe CPS insertion with high-quality navigation, and provides other substantial benefits for cervical spinal instrumentation. Even with current optimized technology, however, CPS perforation cannot be completely prevented, with 8.3% instances of minor violations, which do not cause significant complications, and 2.8% instances of major pedicle violations, which may cause catastrophic complications. Therefore, a combination of intraoperative 3D image-based navigation with other techniques may result in more accurate CPS placement.

Для цитирования: Ishikawa Yoshimoto, Kanemura Tokumi, Yoshida Go, Matsumoto Akiyuki, Ito Zenya, Tauchi Ryoji, Muramoto Akio, Ohno Shuichiro, Nishimura Yusuke. Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion.. Journal of neurosurgery. Spine. 2011. DOI: 10.3171/2011.6.spine10809.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.