DOI 10.1016/j.jvir.2018.08.004
Effectiveness and Safety of Percutaneous CT-Guided Rib Biopsy.
Аннотация
PURPOSE: To retrospectively evaluate effectiveness and safety of percutaneous CT-guided rib biopsy.
MATERIALS AND
METHODS
CT-guided core rib biopsies were performed in 249 consecutive patients between January 2002 and June 2016. Mean patient age was 64.8 years ± 13.8. Additional patient demographics, rib lesion characteristics, and procedural techniques were reviewed. Diagnostic yield was assessed, and complications were classified using SIR criteria.
RESULTS
Mean maximal diameter of 249 rib lesions was 2.7 cm ± 1.8, and 107 (43%) rib lesions had an associated extraosseous soft tissue component. Of rib lesions, 172 (69%) were lytic, 75 (30%) were sclerotic, and 2 (1%) were identifiable only with positron emission tomography/CT correlation. Specimens from 241 (96.8%) biopsies were adequate for pathologic diagnosis, whereas 8 (3.2%) were nondiagnostic. Of diagnostic biopsies, 168 (69.7%) were positive for malignancy; 73 (30.3%) revealed benign etiologies. There was a significant difference in diagnostic biopsy rate depending on size of the rib lesion (mean 2.8 cm ± 1.8 for diagnostic biopsies vs mean 1.3 cm ± 0.5 for nondiagnostic biopsies; P = .007). Of rib lesions, 170 (99%) lytic lesions and 69 (92%) sclerotic lesions yielded diagnostic biopsies; diagnostic biopsy rate was significantly higher for lytic lesions than sclerotic lesions (P = .01). There were 14 (5.6%) minor complications and no major complications.
CONCLUSIONS
Percutaneous CT-guided core rib biopsy resulted in high diagnostic yield and low complications. Diagnostic biopsy rates were higher with larger lesion size and lytic rib lesions.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.