MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0042-1756515

Медицинская библиотека · Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2022

Management of Feline Femoral, Tibial and Humeral Fractures Using a 3.5 mm Titanium Interlocking Nail.

Mund Georg Michael, Bitterli Thomas, Häußler Thomas Christian, Gerwing Martin, Feichtenschlager Christian

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Our objectives were to report complications associated with stabilization of long-bone fractures in cats using a 3.5-mm titanium interlocking nail and to examine the influences of signalment, fracture type and fixation evaluations on the occurrence of complications.

STUDY

DESIGN

Retrospective clinical study.

MATERIAL AND

METHODS

Medical and radiographic records of cats with long-bone fractures treated with an interlocking nail were reviewed. Data included age, sex, weight, cause of the fracture, fractured bone(s) and fracture type. Complications were classified as minor and major complications. Fisher's exact tests and logistic regression analysis were used to test whether certain variables of signalment and interlocking nail configuration had an effect on the occurrence of complications.

RESULTS

Sixty-seven fractures of 67 cats were examined in this study. Forty-eight femora, sixteen tibiae and three humeri were included. Complications occurred in 11/67 fractures. Major complications occurred in 8/67 fractures and included screw breakage (n = 3), nail breakage (n = 2), nail bending (n = 1), screw loosening (n = 1), non-union (n = 1). Statistical analysis showed a significant difference between fracture types and the occurrence of major complications (p = 0.02).

CONCLUSION

In conclusion, use of this commercially available standard 3.5-mm titanium interlocking nail for stabilization of comminuted and oblique humeral, femoral and tibial fractures in cats is feasible.

Для цитирования: Mund Georg Michael, Bitterli Thomas, Häußler Thomas Christian, Gerwing Martin, Feichtenschlager Christian. Management of Feline Femoral, Tibial and Humeral Fractures Using a 3.5 mm Titanium Interlocking Nail.. Veterinary and comparative orthopaedics and traumatology : V.C.O.T. 2022. DOI: 10.1055/s-0042-1756515.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.