Diagnostic Value of Optical Spectral Transmission in Rheumatoid Arthritis: Associations with Clinical Characteristics and Comparison with Joint Ultrasonography.
Аннотация
OBJECTIVE
To examine the value of optical spectral transmission (OST) in detecting joint inflammation in patients with rheumatoid arthritis (RA) and to evaluate whether OST correlates with certain patient characteristics.
METHODS
OST measurements were performed in the metacarpophalangeal, proximal intraphalangeal, and wrist joints of 168 patients with RA and 114 controls. OST difference between the 2 groups was statistically examined and subsequently controlled for the effect of possible confounding factors. Diagnostic OST performance was tested by receiver-operating characteristics. Moreover, associations of OST with clinical and serological activity markers (patient group), joint ultrasound (US; patient subgroup) and various anthropometric and epidemiologic parameters (patient and control group) were evaluated by Spearman correlation coefficient and a generalized linear statistical adjustment model.
RESULTS
OST was significantly higher in the RA group than in the control group, even after adjustment for confounding factors (1.89; 95% CI 0.709-3.070, padj = 0.002). Taking US as a reference, area under the curve for all 1251 joints simultaneously was 0.67 (95% CI 0.631-0.709). In the patient group, correlation and adjustment analyses showed associations of OST with various disease activity markers [28-joint count Disease Activity Score (rho 0.313), swollen joint counts (rho 0.361), C-reactive protein (rho 0.389); all, padj = 0.001], age (rho 0.276, p < 0.001), and osteoarthritis (p = 0.022). Moreover, OST associated with a power Doppler US score (rho 0.442; p = 0.001) and a greyscale US score (rho 0.591; p < 0.001). In both groups males had significantly higher OST values than females and OST associated moderately weakly with body mass index (rho patients 0.316, rho controls 0.24; all, p < 0.001).
CONCLUSION
Patients with RA showed higher OST values in comparison to controls. Moreover, OST associated with clinical, US, and laboratory disease activity markers.