MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-022-09286-1

Медицинская библиотека · European radiology · 2022

Evaluation of myocardial viability in patients with myocardial ischemia reperfusion injury using the dual-energy CT myocardial blood pool imaging.

Ji Qingyu, Wang Yuan, Zhao Ying, Chen Qingwei, Gao Yanfeng, Zhou Maorong, Liu Baoliang, Han Ruijuan, Sun Kai

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate myocardial viability in patients with myocardial ischemia reperfusion injury (MIRI) via dual-energy computed tomography myocardial blood pool imaging (DECT MBPI).

METHODS

Between September 2017 and January 2019, we prospectively recruited 59 patients with acute myocardial infarction (AMI) who developed MIRI after revascularization during invasive coronary angiography (ICA). Then, they received DECT MBPI, SPECT, and PET sequentially within 1 week after the onset of MIRI. A total of 1003 myocardial segments of 59 patients were recruited for this study. The iodine reduction areas and delayed enhancement areas were calculated by cardiac iodine map with SPECT rest myocardial perfusion imaging (MPI) + PET myocardial metabolism imaging (MMI) as reference criteria. The paired sample t-test was used to measure the difference of the myocardial iodine value. Cohen's Kappa analysis was used to test the consistency among different observers. ROC analysis was used to calculate the myocardial viability of DECT MBPI.

RESULTS

ROC showed the AUCs of DECT MBPI iodine value to identify a normal myocardium, an ischemic myocardium, and an infarcted myocardium were 0.957, 0.900, and 0.906 (p < 0.001). The sensitivity, specificity, and accuracy of DECT MBPI in identifying an ischemic myocardium were 87.6%, 89.3%, and 97.9% (p < 0.001). The sensitivity, specificity, and accuracy of DECT MBPI in identifying an infarcted myocardium were 88.9%, 92.2%, and 98.6% (p < 0.001). The cutoff value for DECT MBPI to differentiate between an ischemic and a normal myocardium was 0.84 mg I/mL. The cutoff value for DECT MBPI to differentiate between an infarct and a normal myocardium was 2.01 mg I/mL.

CONCLUSION

DECT MBPI can be used to assess myocardial viability in patients with MIRI with high sensitivity and specificity.

KEY POINTS: • Dual-energy computed tomography myocardial blood pool imaging (DECT MBPI) can evaluate myocardial viability of myocardial ischemia-reperfusion injury (MIRI). • DECT MBPI is a non-invasive and timesaving method for evaluation on myocardial ischemia-reperfusion injury in patients with acute myocardial infarction after coronary intervention.

Для цитирования: Ji Qingyu, Wang Yuan, Zhao Ying, Chen Qingwei, Gao Yanfeng, Zhou Maorong, Liu Baoliang, Han Ruijuan, Sun Kai. Evaluation of myocardial viability in patients with myocardial ischemia reperfusion injury using the dual-energy CT myocardial blood pool imaging.. European radiology. 2022. DOI: 10.1007/s00330-022-09286-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.