MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jspd.2018.01.004

Медицинская библиотека · Spine deformity · 2018

Interpretation of Spinal Radiographic Parameters in Patients With Transitional Lumbosacral Vertebrae.

Zhou Peter L, Moon John Y, Tishelman Jared C, Errico Thomas J, Protopsaltis Themistocles S, Passias Peter G, Buckland Aaron J

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

Retrospective radiographic review.

OBJECTIVES

To understand the effect of variability in sacral endplate selection in transitional lumbosacral vertebrae (TLSV) and its impact on pelvic, regional, and global spinal alignment parameters.

BACKGROUND

TLSV can have the characteristics of both lumbar and sacral vertebrae. Difficulties in identification of the S1 endplate may come from nomenclature, number of lumbar vertebrae, sacra, and morphology and may influence the interpretation and consistency of spinal alignment parameters.

METHODS

Patients with TLSV were identified and radiographic measurements including pelvic incidence (PI), pelvic tilt (PT), sacral slope (SS), lumbar lordosis (LL), sagittal vertical axis (SVA), T1-pelvic angle (TPA), pelvic incidence-lumbar lordosis (PI-LL) mismatch, thoracic kyphosis (TK), and spinal inclination (T1SPi) were obtained. Radiographic measurements were performed twice with the sacral endplate at the cephalad and caudal options. Paired t tests assessed the difference between different selection groups.

RESULTS

Of 1,869 patients, 70 (3.7%) were found to have TLSV on radiographic imaging. Fifty-eight (82.9%) had lumbarized sacral segments whereas 12 (17.1%) had sacralized lumbar segments. T1-SPi (mean: -1.77°) and TK (mean: 34.86°) did not vary from altering sacral endplate selection. Selection of the caudal TLSV as the sacral endplate resulted in an increase in all pelvic parameters (PI: 66.8° vs. 44.3°, PT: 25.1° vs. 12.7°, and SS: 41.6° vs. 31.6°), regional lumbar parameters (LL: -54.1° vs. 44.0°, PI-LL: 12.7° vs. 0.3°), and global parameters (SVA: 46.1 mm vs. 28.3 mm, TPA: 23.3° vs. 10.8°) as compared to selecting the cephalad TLSV. All mean differences between radiographic parameters were found to be statistically significant (p < .001).

CONCLUSIONS

Variation in sacral endplate selection in TLSV significantly affects spinal alignment parameter measurements. A standardized method for measuring TLSV is needed to reduce measurement error and ultimately allow more accurate understanding of alignment targets in patients with TLSV.

LEVEL OF EVIDENCE: Level III.

Для цитирования: Zhou Peter L, Moon John Y, Tishelman Jared C, Errico Thomas J, Protopsaltis Themistocles S, Passias Peter G, Buckland Aaron J. Interpretation of Spinal Radiographic Parameters in Patients With Transitional Lumbosacral Vertebrae.. Spine deformity. 2018. DOI: 10.1016/j.jspd.2018.01.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.