Rate of avascular necrosis following proximal humerus fractures treated with a lateral locking plate and endosteal implant.
Аннотация
INTRODUCTION
Treatment of displaced proximal humerus fractures remains challenging. The introduction of locking plates has renewed interest in treating these fractures with joint-preserving techniques rather than hemiarthroplasty, but high complication rates are still reported. Avascular necrosis is not solely dependent on the initial fracture pattern, but can also result from intraoperative and postoperative vascular insults.
METHOD: We describe a technique to minimize disruption of humeral head blood supply and maximize fracture fixation. A total of 34 patients with complex proximal humerus fractures were treated with a locking plate and endosteal implant through an anterolateral approach and followed for an average of 66 weeks to determine the rates of avascular necrosis.
RESULTS
No patient suffered complete osteonecrosis (0%) and only one patient suffered partial necrosis (2.8%) of the humeral head. The length of the posteromedial hinge was not predictive of this complication.
CONCLUSION
Use of the anterolateral approach and endosteal augment of a lateral locking plate can minimize avascular necrosis following proximal humerus fracture.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.