MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/atm-22-447

Медицинская библиотека · Annals of translational medicine · 2022

Novel application of 3D printed microporous prosthesis to repair humeral nonunion with segmental bone defects: a case report.

Qiu Weipeng, Liu Bingchuan, Li Xingcai, Tian Yun

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Nonunion of the humeral shaft can turn into bone defects. There is no consensus on the optimal treatment of humeral shaft nonunion with bone defects. Herein, we presented a single case of a patient with a 9.5 cm humerus shaft bone defect treated with a 3D printed Ti6Al4V microporous prosthesis after internal fixation failure of a middle-inferior humerus fracture.

CASE DESCRIPTION: A 53-year-old female who injured her left upper limb by falling was diagnosed with a fracture of the left humeral shaft. The fracture was treated with open reduction and internal fixation. Nine months postoperatively, radiography examination indicated humeral nonunion with a 9.5 cm segmental bone defect. A 3D printing technology was then used to design and fabricate a customized microporous prosthesis with an intramedullary nail and lateral plates. A two-stage surgical strategy was performed, including radical debridement, temporary fixation for the induced membrane formation, and the implantation of the prosthesis. At 18 months of follow-up, encouraging clinical outcomes were observed. The prosthesis remained stable in the original implantation area and callus formation was found at the contact end of the prosthesis and bone stump. The upper limb functions returned to normal with a satisfactory functional score. Also, no complications were found.

CONCLUSIONS

Reconstruction with a 3D printed microporous prosthesis might be used as an alternative for the repair of large segmental bone defects of limbs.

Для цитирования: Qiu Weipeng, Liu Bingchuan, Li Xingcai, Tian Yun. Novel application of 3D printed microporous prosthesis to repair humeral nonunion with segmental bone defects: a case report.. Annals of translational medicine. 2022. DOI: 10.21037/atm-22-447.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.