Artificial organs · 2012
Modified metaphyseal-loading anterolaterally flared anatomic femoral stem: five- to nine-year prospective follow-up evaluation and results of three-dimensional finite element analysis.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kokubo Yasuo, Uchida Kenzo, Oki Hisashi, Negoro Kohei, Nagamune Kouki, Kawaguchi Shogo, Takeno Kenichi, Yayama Takafumi, Nakajima Hideaki, Sugita Daisuke, Yoshida Ai, Baba Hisatoshi
Аннотация
We have designed a proximal-fitting, anterolaterally flared, arc-deposit hydroxyapatite-coated anatomical femoral stem (FMS-anatomic stem; KYOCERA Medical, Osaka, Japan) for cementless total hip arthroplasty (THA) for Japanese patients with dysplastic hip osteoarthritis, using a nonlinear three-dimensional finite element analysis simulating loading conditions. The Anatomic Fit stem was modified in the region of the arc-sprayed surface, to allow more proximal appearance of spot welds. The aim of the present study was to analyze the clinical and radiographic outcomes of patients who underwent THA using this stem. We reviewed 73 consecutive patients (79 hips; 13 men 16 hips; 60 women 63 hips; age at surgery, 57.6 years, range, 35-78) who underwent cementless THA using the Anatomic Fit stem, at a follow-up period of 7.1 years (range, 5.1-9.4). Harris Hip score improved from 40.7 ± 17.1 before surgery to 91.0 ± 5.2 points at follow-up. The 7.1-year stem survival rate was 100%. Radiographs at follow-up confirmed the stability of the femoral stems within the femoral canal in all cases, with sufficient bone ingrowth. None of the patients had subsidence of the stem exceeding 2.0 mm within the femoral canal or changes in varus or valgus position of more than 2.0°. The Anatomic Fit stem provided excellent results. The nonlinear three-dimensional finite element analysis demonstrated that the stem-bone relative motion was 10 µm at the proximal end of the stem and proximal load transfer. Our analysis confirmed reduced radiolucency around the stem, minimal subsidence, appropriate stress shielding, and promising medium-term stability within the femoral canal.
Предметные рубрики MeSH
AdultAgedArthroplasty, Replacement, HipBiomechanical PhenomenaCase-Control StudiesCoated Materials, BiocompatibleComputer-Aided DesignDurapatiteFemaleFemurFinite Element AnalysisFollow-Up StudiesHip Dislocation, CongenitalHip JointHip ProsthesisHumansJapanMaleMiddle AgedNonlinear DynamicsOsseointegrationOsteoarthritis, HipProspective StudiesProsthesis DesignRadiographyRange of Motion, ArticularRecovery of FunctionStress, MechanicalTime FactorsTreatment OutcomeWeight-Bearing