MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-004-0761-x

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2004

Measurement of angular and linear segmental lumbar spine flexion-extension motion by means of image registration.

Penning L, Irwan R, Oudkerk M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The presently available method of measuring segmental lumbar spine mobility by means of superimposition of lumbar spine radiographs in flexion and extension lacks precision due to differences in the cortical outline of the vertebral bodies in flexed and extended position. The introduction of digital image processing has opened the possibility of computerised superimposition ('matching') of digital vertebral body images by means of image registration. Theoretically this technique allows more accurate image matching and, consequently, greater precision of measurement because the whole vertebral body image (not only its cortical outline) can be chosen as region of interest, with registration of all available digital information within this region.

METHODS

To check accuracy and convenience of the new method, two computer program experts performed five image registration measurements of the five lumbar motion segments in five consecutive flexion-extension studies of old lumbar fracture, spondylolytic spondylolisthesis and degenerative anterolisthesis. For comparison an experienced radiologist performed the same repeated measurements with the manual superimposition method.

RESULTS

Measurement error of the image registration method proved to be significantly smaller than that of the manual superimposition method. There was no overlap between the 95% confidence intervals of the mean standard deviations of experts A and B using the image registration method and the 95% confidence interval of the mean standard deviations of the experienced radiologist using the manual superimposition method. Besides, the image registration method proved to be more convenient because the whole procedure from import of the image data to display of the measurement outcomes lasted 2-3 min compared to 3-6 min for the superimposition method.

Для цитирования: Penning L, Irwan R, Oudkerk M. Measurement of angular and linear segmental lumbar spine flexion-extension motion by means of image registration.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2004. DOI: 10.1007/s00586-004-0761-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.