MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/03635465221124277

Медицинская библиотека · The American journal of sports medicine · 2022

Morphometric and Biomechanical Comparison of the Scapular Spine and Coracoid Graft in Anterior Shoulder Instability.

Kuan Fa-Chuan, Hsu Kai-Lan, Lin Fang-Hsien, Hong Chih-Kai, Chen Yueh, Shih Chien-An, Su Wei-Ren

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The scapular spine has been described as a relatively new bone graft alternative used in glenoid augmentation. The classic Latarjet procedure, which transfers the coracoid as a graft, is regarded as the gold standard. The comparison of these 2 techniques has not been fully reported.

PURPOSE: To compare the anatomic and biomechanical properties of glenoid augmentation using scapular spine graft or coracoid graft.

STUDY

DESIGN

Controlled laboratory study.

METHODS

The study used 20 fresh-frozen human cadaveric shoulders. A 25% anterior glenoid defect was created, and the specimens were divided randomly to receive glenoid augmentation by scapular spine or coracoid grafts. For both procedures, the grafts were secured to the glenoid defect with 2 screws. Morphometric data, including the glenoid articular area, amount of restoration, and graft dimensions, were obtained. A biomechanical test was conducted in a direct-loading scenario. The construct stiffness, cyclic displacement, and ultimate failure of each specimen were collected.

RESULTS

No significant difference was found in glenoid articular restoration between the scapular spine group and the coracoid group (31% vs 33%, respectively; P = .311). Morphometric analysis indicated that coracoid grafts exhibited significantly greater thickness and height than scapular spine grafts. In biomechanical results, the scapular spine group exhibited significantly greater construct stiffness than the coracoid group (206.3 ± 58.8 vs 148.3 ± 76.0 N/mm, respectively; P = .023). The average failure load in the scapular spine group was not significantly higher than that in the coracoid group. No significant differences in cyclic displacement were found between the 2 techniques.

CONCLUSION

In a simulated 25% anterior glenoid bony defect, a scapular spine graft was comparable with the classic Latarjet procedure in restoring the glenoid articular dimension and exhibited superior construct stiffness in a cadaveric model.

CLINICAL RELEVANCE: The scapular spine may serve as an alternative graft choice in glenoid augmentation surgery considering the amount of articular restoration and initial fixation stability.

Для цитирования: Kuan Fa-Chuan, Hsu Kai-Lan, Lin Fang-Hsien, Hong Chih-Kai, Chen Yueh, Shih Chien-An, Su Wei-Ren. Morphometric and Biomechanical Comparison of the Scapular Spine and Coracoid Graft in Anterior Shoulder Instability.. The American journal of sports medicine. 2022. DOI: 10.1177/03635465221124277.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.