MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/ani14091381

Медицинская библиотека · Animals : an open access journal from MDPI · 2024

Minimally Invasive Plate Osteosynthesis (MIPO) of Comminuted Radial Fractures Using a Locking Plate Contoured on a 3D-Printed Model of the Feline Antebrachium: A Cadaveric Study.

Trębacz Piotr, Frymus Jan, Pawlik Mateusz, Barteczko Anna, Kurkowska Aleksandra, Czopowicz Michał

СтатьяПеревод в очереди

Аннотация

(1)

Background

Due to the unique structural and functional characteristics of the forelimb in cats, fractures of the radius and ulna are best repaired using internal fixation and stabilization in accordance with AO principles. This study presents the results of reduction of 42 cadaveric comminuted feline radial fractures reduced by minimally invasive plate osteosynthesis (MIPO). (2)

Methods

Radius fractures were created on 21 pairs of forelimbs with intact bones. MIPO was then performed using two locking bone plates pre-contoured on 3D-printed bone models of the antebrachium of a male and a female cat. Pre- and postoperative radiographs were taken, and radius length and anatomical lateral distal radial angle (aLDRA) were measured. (3)

Results

All fractures were classified as complex diaphyseal fractures of the radius. The radial bone length did not change significantly after surgery (F1,18 = 0.01, p = 0.933). However, the aLDRA was modified after surgery (F1,18 = 7.51, p = 0.013), but this change was only observed in females, in whom the aLDRA was significantly reduced (p = 0.035) compared to the value determined by the shape of the plate. In males, the pre- and postoperative aLDRA values were similar (p = 0.824). In 40 cases, alignment, adjacency of bone fragments, and apparatus were judged to be satisfactory. In two cases, the plate was fixed to the proximal radius and distal ulna due to misidentification of the distal radius. In both cases, revision surgery and correct fixation of the radius gave proper alignment, adjacency, and apparatus. (4)

Conclusion

A pre-contoured plate on a 3D-printed model of the male and female domestic cat antebrachium was suitable for the reduction and stabilization of comminuted radial fractures in a cohort of domestic cat cadavers without the need to print individual antebrachial bone models for each patient.

Для цитирования: Trębacz Piotr, Frymus Jan, Pawlik Mateusz, Barteczko Anna, Kurkowska Aleksandra, Czopowicz Michał. Minimally Invasive Plate Osteosynthesis (MIPO) of Comminuted Radial Fractures Using a Locking Plate Contoured on a 3D-Printed Model of the Feline Antebrachium: A Cadaveric Study.. Animals : an open access journal from MDPI. 2024. DOI: 10.3390/ani14091381.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.