MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/annrheumdis-2018-213393

Медицинская библиотека · Annals of the rheumatic diseases · 2018

Improved detection of erosions in the sacroiliac joints on MRI with volumetric interpolated breath-hold examination (VIBE): results from the SIMACT study.

Diekhoff Torsten, Greese Juliane, Sieper Joachim, Poddubnyy Denis, Hamm Bernd, Hermann Kay-Geert A

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To compare the performance of a new three-dimensional MRI sequence (volumetric interpolated breath-hold examination; MR-VIBE) with a conventional T1-weighted sequence (MR-T1) for the detection of erosions in the sacroiliac joints (SIJs) using low-dose CT (ldCT) as reference.

METHODS

ldCT and T1-MRI and MR-VIBE of 110 prospectively included patients with low back pain and suspected axial spondyloarthritis (axSpA) were scored for erosions by two readers. The presence of erosions on the patients' level, the erosion sum score, sensitivity and specificity of both MRI sequences using ldCT as a reference as well as agreement between the readers were assessed.

RESULTS

MR-VIBE had a higher sensitivity than MR-T1 (95% vs 79%, respectively) without a decrease in specificity (93% each). MR-VIBE compared with MR-T1 identified 16% more patients with erosions (36 vs 30 of 38 patients with positive ldCT findings). The erosion sum score was also higher for MR-VIBE (8.1±9.3) than MR-T1 (6.7±8.4), p=0.003. The agreement on erosion detection was also higher for MR-VIBE (κ=0.71) compared with MRI-T1 (κ=0.56).

CONCLUSION

VIBE detected erosions in the SIJs with higher sensitivity without a loss of specificity and superior reliability compared with a standard T1-weighted sequence. Its value for the diagnosis of axSpA has still to be determined.

Для цитирования: Diekhoff Torsten, Greese Juliane, Sieper Joachim, Poddubnyy Denis, Hamm Bernd, Hermann Kay-Geert A. Improved detection of erosions in the sacroiliac joints on MRI with volumetric interpolated breath-hold examination (VIBE): results from the SIMACT study.. Annals of the rheumatic diseases. 2018. DOI: 10.1136/annrheumdis-2018-213393.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.