DOI 10.1002/jbmr.5650070310

Медицинская библиотека · Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research · 1992

Sequential and precise in vivo measurement of bone mineral density in rats using dual-energy x-ray absorptiometry.

Ammann P, Rizzoli R, Slosman D, Bonjour J P

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

In the design of new strategies for the treatment of osteoporosis, noninvasive, precise, and sensitive bone mass measurement capable of detecting changes over short periods of time in small animals is essential. Most of the models described thus far require the sacrifice of the animals and/or display low reproducibility. Using a dual-energy x-ray absorptiometer (DEXA; Hologic QDR-1000) in an ultrahigh-resolution mode, we measured bone mineral density (BMD) in rats at the levels of lumbar spine (L1-4), proximal tail (caudal vertebrae C2-4), and tibia. Accuracy was evaluated by measuring the mineral content of bone powder capsules (within the range of rat vertebrae BMD), under 0.5-3 cm water to mimic variations in soft tissue thickness. The bone powder capsule mineral content was highly correlated with chemically determined hydroxyapatite content (r = 0.999). In vivo reproducibility was evaluated by calculating the coefficient of variation (CV = 100 x SD/mean) of four to six BMD measurements, each time with repositioning, in seven rats (220-500 g body weight). CV was 1.36 +/- 0.32% (x +/- SD) for lumbar spine, 0.66 +/- 0.50% for proximal tail, and 1.12 +/- 0.45% for tibia. The ability to detect BMD changes was investigated by measuring BMD before and every 4 weeks after ovariectomy (OVX) in 270 g rats, pair fed during the whole experiment. Compared with sham-operated control animals, a highly significant difference in lumbar spine BMD was observed 4 weeks after OVX, which reached a maximum by 8 weeks and remained stable thereafter. At the level of the proximal tibia, the difference was maximal 4 weeks after OVX.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Ammann P, Rizzoli R, Slosman D, Bonjour J P. Sequential and precise in vivo measurement of bone mineral density in rats using dual-energy x-ray absorptiometry.. Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research. 1992. DOI: 10.1002/jbmr.5650070310.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.