MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/cid/ciaf561

Медицинская библиотека · Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2026

Diagnostic Accuracy of the STANDARD F TB-Feron FIA Assay for Tuberculosis Infection in Vietnam: A Cross-Sectional Study.

Nguyen Han Thi, Vo Luan Nguyen Quang, Codlin Andrew James, Forse Rachel, Wingfield Tom, Annerstedt Kristi Sidney, MacLean Emily Lai-Ho, Creswell Jacob, Kirubi Beatrice, Nguyen Hoa Binh, Van Dinh Luong, Doan Ha Thu, Forsman Lina Davies, TBI Testing Team

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Tuberculosis (TB) infection is a driver of the global TB epidemic. Accurate, affordable, and simpler diagnostics are crucial for identifying people for preventive therapy. We evaluated the diagnostic performance of the STANDARD F TB-Feron FIA (TB-Feron), a near-point-of-care (POC) assay for detecting TB infection.

METHODS

From June to December 2024, we conducted a cross-sectional study at the Vietnam National Lung Hospital, enrolling 352 participants, including 345 eligible participants: 95 with microbiologically confirmed pulmonary TB (Group 1), 200 household contacts of people with pulmonary TB (Group 2), and 50 with a recent history of a negative QFT-Plus result and no known TB exposure (Group 3). Participants were tested with TB-Feron and the reference standard, QuantiFERON TB Gold Plus (QFT-Plus). Results were compared for sensitivity and specificity (primary endpoints), with inter-test agreement (Cohen's κ) and reproducibility (Bland-Altman analysis) as secondary outcomes.

RESULTS

Among 345 eligible participants, TB-Feron sensitivity was 88.4% (95% confidence interval [CI] 80.2-94.1) in Group 1, and specificity was 70.0% (55.4-82.1) in Group 3. In Group 2, positive and negative agreements with QFT-Plus were 89.2% (79.8-95.2%) and 75.4% (66.9-82.6), respectively, with inter-test agreement of 80.5% (Cohen's κ=0.6069, P < .0001). Intra-test reproducibility showed no significant differences in IFN-γ levels (mean difference = 2.08 IU/mL, 95% CI -1.28 to 5.44, P = .206).

CONCLUSIONS

With high sensitivity, the TB-Feron assay is a potential near-POC alternative to the QFT-Plus assay for diagnosing TB infection, but requires consideration of its suboptimal specificity.

Для цитирования: Nguyen Han Thi, Vo Luan Nguyen Quang, Codlin Andrew James, Forse Rachel, Wingfield Tom, Annerstedt Kristi Sidney, MacLean Emily Lai-Ho, Creswell Jacob, Kirubi Beatrice, Nguyen Hoa Binh, Van Dinh Luong, Doan Ha Thu, Forsman Lina Davies, TBI Testing Team. Diagnostic Accuracy of the STANDARD F TB-Feron FIA Assay for Tuberculosis Infection in Vietnam: A Cross-Sectional Study.. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America. 2026. DOI: 10.1093/cid/ciaf561.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.