Vitamin D deficiency adversely affects early post-operative functional outcomes after total knee arthroplasty.
Аннотация
PURPOSE: Vitamin D has received considerable attention in recent years owing to the increasing evidence of its importance in muscle function and physical performance. The present study attempted to determine whether patients with low serum vitamin D levels had impairment in early functional outcomes following total knee arthroplasty (TKA).
METHODS
This was a prospective cohort study that included 92 patients. Patients were divided into two groups according to their vitamin D levels as assessed at the preoperative visit: (1) vitamin D-deficient group, serum 25-hydroxyvitamin D3 (25(OH)D) levels <12 ng/mL; (2) vitamin D non-deficient group, serum 25(OH)D levels ≥12 ng/mL. American Knee Society Score (KSS) and four other performance tests including the alternative step test (AST), six-metre walk test (SMT), sit-to-stand test (STS), and timed up and go test (TUGT) were used for assessment of post-operative function. All assessments were performed one day before and three months after TKA.
RESULTS
Of the 92 patients included in the study, 87 patients performed all required assessments. The mean post-operative functional KSS was significantly lesser in the vitamin D-deficient group than in the vitamin D non-deficient group (67.2 vs. 73.4, p = 0.031). The mean values of time taken for post-operative AST (16.6 vs. 14.6 s, p = 0.033) and SMT (8.8 vs. 7.7 s, p = 0.012) were significantly longer in the vitamin D-deficient group than in the vitamin D non-deficient group. Post-operative STS and TUGT demonstrated higher values for mean time taken in the vitamin D-deficient group than in the vitamin D non-deficient group, but these were not statistically significant (13.6 vs. 12.4 s, not significant (n.s.); 12.7 vs. 11.7 s, n.s., respectively).
CONCLUSION
Early post-operative functional outcomes following TKA appear to be adversely affected by vitamin D deficiency.
LEVEL OF EVIDENCE: Prospective cohort study, Level II.