MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2018.08.019

Медицинская библиотека · The Journal of arthroplasty · 2018

Conventional Polyethylene in Total Hip Arthroplasty in Young Patients: Survivorship, Wear Analysis, and Clinical Outcomes Between 15 and 20 Years.

Stambough Jeffrey B, Rames Richard D, Pashos Gail E, Maloney William J, Martell John M, Clohisy John C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Total hip arthroplasty (THA) remains a successful procedure for most patients. However, there is a paucity of information regarding the long-term performance of conventional polyethylene (CPE) bearings in young patients undergoing THA.

METHODS

After accounting for incomplete follow-up of a prospective cohort of 123 THAs in patients ≤50 years, we performed a retrospective review of 101 hips in 84 patients (82.1%) with an average 17.1-year follow-up (14.7-19.6 years). Outcomes of interest included linear and volumetric wear, clinical outcome scores, implant survivorship, and patient mortality. Wear rates were calculated using Martell Software.

RESULTS

Wear analysis revealed median linear and volumetric wear rates of 0.106 mm/y (confidence interval, 0.079-0.133) and 43.58 mm3/y (confidence interval, 33.4-53.75). The modified Harris hip scores improved by 36 points while University of California, Los Angeles activity scores improved by 2.0 points at 15-year follow-up (P < .0001). Twenty-two hips (21.8%) were revised, 13 of which (12.8%) were for wear-related causes at an average of 14.9 years (range, 9.2-21 years) from index arthroplasty. There was significantly higher mortality in patients with a preoperative diagnosis of inflammatory avascular necrosis (P = .015).

CONCLUSION

Because CPE was commonly used in THA over the last 25 years, it is important to understand its implications on the growing revision burden. Significant concerns exist with regard to the long-term durability of CPE bearings in young, moderately active patients 15 years after THA. These patients should be followed closely for wear-related problems. Our results should be used as a comparison when evaluating the outcomes of more modern bearing surface combinations.

Для цитирования: Stambough Jeffrey B, Rames Richard D, Pashos Gail E, Maloney William J, Martell John M, Clohisy John C. Conventional Polyethylene in Total Hip Arthroplasty in Young Patients: Survivorship, Wear Analysis, and Clinical Outcomes Between 15 and 20 Years.. The Journal of arthroplasty. 2018. DOI: 10.1016/j.arth.2018.08.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.