MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fmed.2026.1851512

Медицинская библиотека · Frontiers in medicine · 2026

Dry eye disease in axial spondyloarthritis: heterogeneous ocular surface dysfunction involving tear film instability and tear production from the AIDA network registry.

Caggiano Valeria, Vitale Antonio, Sbalchiero Jessica, Tufan Abdurrahman, Guaracha-Basañez Guillermo Arturo, Kawakami-Campos Perla Ayumi, Hinojosa-Azaola Andrea, Duran Rahime, Kucuk Hamit, Ragab Gaafar, Ruscitti Piero, Lopalco Giuseppe, Karamanakos Anastasios, Fotis Lampros, Ghanema Mahmoud, Cipriani Paola, Morrone Maria, Dimouli Aikaterini, Kourtesi Katerina, Tharwat Samar, Moshrif Abdelhfeez, Sota Jurgen, Mayo-Juanatey Adrián, Boyarchuk Oksana, Edrees Amr, Barone Patrizia, Carubbi Francesco, Chimenti Maria Sole, Conforti Alessandro, Thabet Maissa, Opris-Belinski Daniela, Erten Şükran, Hegazy Mohamed Tharwat, Mazzei Maria Antonietta, Piscitello Chiara, Frediani Bruno, Balistreri Alberto, Cifuentes-González Carlos, de-la-Torre Alejandra, Cantarini Luca, Fabiani Claudia

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Dry eye disease (DED) has been described in axial spondyloarthritis (axSpA), but patterns of tear fluid and ocular surface involvement remain incompletely characterized. This study aims to evaluate tear film instability and tear production in axSpA and explore the heterogeneity of DED manifestations.

METHODS

Axial spondyloarthritis patients and healthy controls underwent non-invasive tear break-up time (niTBUT), Schirmer test, and Ocular Surface Disease Index (OSDI)- 6 evaluation. Group differences were assessed using niTBUT thresholds (<10 s and <5 s).

RESULTS

Mean niTBUT was significantly lower in axSpA patients than controls (7.85 ± 5.63 vs. 10.61 ± 5.27 s; p < 0.001); niTBUT <5 s, but not <10 s, differentiated groups (p = 0.003 and p = 0.105, respectively). ROC analysis identified an optimal niTBUT cut-off of 5.15 s. Schirmer values also discriminated axSpA patients from controls, with an optimal threshold of 4.5 mm. Agreement between niTBUT and Schirmer classification was weak (Cohen κ = 0.18). OSDI-6 scores were not significantly associated with pathological niTBUT. The niTBUT values were significantly associated with patients' age, but the diagnosis of axSpA accounted for the main determinant of niTBUT <5 s (likelihood ratio test, p = 0.026).

CONCLUSION

Within the present cohort, a niTBUT <5 s showed greater discriminative performance than the conventional 10-s cut-off and may identify a subgroup of axSpA patients with more severe tear film instability. Aging contributes to tear film instability, but axSpA independently contributes to severe niTBUT impairment. Tear film instability and reduced tear secretion are both involved in DED affecting axSpA patients.

Для цитирования: Caggiano Valeria, Vitale Antonio, Sbalchiero Jessica, Tufan Abdurrahman, Guaracha-Basañez Guillermo Arturo, Kawakami-Campos Perla Ayumi, Hinojosa-Azaola Andrea, Duran Rahime, Kucuk Hamit, Ragab Gaafar, Ruscitti Piero, Lopalco Giuseppe, Karamanakos Anastasios, Fotis Lampros, Ghanema Mahmoud, Cipriani Paola, Morrone Maria, Dimouli Aikaterini, Kourtesi Katerina, Tharwat Samar, Moshrif Abdelhfeez, Sota Jurgen, Mayo-Juanatey Adrián, Boyarchuk Oksana, Edrees Amr, Barone Patrizia, Carubbi Francesco, Chimenti Maria Sole, Conforti Alessandro, Thabet Maissa, Opris-Belinski Daniela, Erten Şükran, Hegazy Mohamed Tharwat, Mazzei Maria Antonietta, Piscitello Chiara, Frediani Bruno, Balistreri Alberto, Cifuentes-González Carlos, de-la-Torre Alejandra, Cantarini Luca, Fabiani Claudia. Dry eye disease in axial spondyloarthritis: heterogeneous ocular surface dysfunction involving tear film instability and tear production from the AIDA network registry.. Frontiers in medicine. 2026. DOI: 10.3389/fmed.2026.1851512.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.