MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-024-07415-z

Медицинская библиотека · BMC musculoskeletal disorders · 2024

Volar fixed plating of distal radius fractures: optimizing plate position for enhanced clinical outcomes.

Emet Abdulsamet, Veizi Enejd, Karaman Yavuz, Akgun Erkan, Tolunay Tolga, Firat Ahmet

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The precise influence of plate position on clinical outcomes in the context of volar fixed-angle plating for distal radius fractures is not fully understood. This article aims to investigate the influence of plate position on clinical results, and functional outcomes in patients treated with volar fixed plating for distal radius fractures.

METHODS

A total of 58 patients with 64 distal radius fractures were included in the study. Patient demographics, fracture characteristics, surgical details, and radiographic data were collected. Post-operative AP and Lat views of all patients taken on the first day after surgery were evaluated. Volar Tilt, Radial Inclination and Radial Height measurements were used as reduction criteria. In the follow-up, the patients were called for their last control, flexion and extension angles of the wrist and Mayo Wrist Scores, the distance of the plate to the joint line and the angle between the plate and the radial shaft were measured and recorded.

RESULTS

A total of 64 distal radius fractures, with a mean age of 46.9 years, and the mean follow-up period 24.9 months were included in this study. There was a significant relationship between the Radial Inclination and Plate-Shaft Angle variables and the Mayo Wrist Score at a 99% confidence interval. Additionally, a relationship was observed between the Radial Height variable and the Mayo Score at a 90% confidence interval. A significant positive association was observed between radial inclination and achieving a Good-to-Excellent Mayo score (OR = 1.28, 95% CI [1.08-1.51], p = 0.004). Plate distance to joint line demonstrated a marginally significant positive association with a Good-to-Excellent Mayo score (OR = 1.31, 95% CI [0.97-1.77], p = 0.077). Univariate analysis revealed a significant negative association between plate-shaft angle and achieving a Good-to-Excellent Mayo score (OR = 0.71, 95% CI [0.52-0.99], p = 0.045). This negative association remained statistically significant in the multivariate analysis (p = 0.016).

CONCLUSION

Radial inclination, plate distance to joint line, and angle between plate and radius shaft were identified as significant factors associated with improved Mayo Wrist Scores.

Для цитирования: Emet Abdulsamet, Veizi Enejd, Karaman Yavuz, Akgun Erkan, Tolunay Tolga, Firat Ahmet. Volar fixed plating of distal radius fractures: optimizing plate position for enhanced clinical outcomes.. BMC musculoskeletal disorders. 2024. DOI: 10.1186/s12891-024-07415-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.