Superior Capsule Reconstruction With Fascia Lata Allograft Has Initial Stiffness and Ultimate Load Comparable to the Native Shoulder Superior Capsule: A Cadaveric Biomechanical Study.

DeBellis Nicholas, Tibone James E, Manning John, Hung Victor, McGarry Michelle H, Adamson Gregory J, Lee Thay Q

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The purpose of this study was to compare the biomechanical characteristics of a fascia lata superior capsule reconstruction (FL-SCR) to the native superior capsule.

METHODS

The native superior capsule of 8 cadaveric shoulders was tested with cyclic loading from 10 to 50 N for 30 cycles in 20° of glenohumeral abduction followed by load to failure at 60 mm/min. Following native superior capsule testing, FL-SCR was performed, which was tested as described for the native capsule. Paired t test was used for statistical analyses with P < .05 for significance.

RESULTS

The stiffness for cycle 1 to 50 N was significantly higher for the native superior capsule compared to the FL-SCR (P = .001). By cycle 30, the stiffness between the two was not statistically different (P = .734). During load to failure, the initial stiffness to 2 mm for the FL-SCR and the native superior capsule was not statistically different (P = .262). The linear stiffness and yield load of the native superior capsule were significantly greater than that of the FL-SCR (94.5 vs 28.0 N/mm, P = .013; 386.9 vs 123.8 N, P = .029). There was no significant difference in ultimate load between the native superior capsule and the FL-SCR (444.9 vs 369.0 N, P = .413).

CONCLUSIONS

FL-SCR has initial stiffness and ultimate load similar to the native superior capsule.

CLINICAL RELEVANCE: The biomechanical properties of FL allograft make it an appealing option as a graft choice for superior capsule reconstruction.

Для цитирования: DeBellis Nicholas, Tibone James E, Manning John, Hung Victor, McGarry Michelle H, Adamson Gregory J, Lee Thay Q. Superior Capsule Reconstruction With Fascia Lata Allograft Has Initial Stiffness and Ultimate Load Comparable to the Native Shoulder Superior Capsule: A Cadaveric Biomechanical Study.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2022. DOI: 10.1016/j.arthro.2022.07.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.