Usability and training differences between two personal insulin pumps.

Schaeffer Noel E, Parks Linda J, Verhoef Erik T, Bailey Timothy S, Schorr Alan B, Davis Trent, Halford Jean, Sulik Becky

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The purpose of this study was to determine if there were usability and training differences between the Medtronic MiniMed Paradigm Revel Insulin Pump and the Tandem Diabetes Care t:slim Insulin Pump during use by representative users, performing representative tasks, in a simulated use environment. This study utilized a between-subjects experimental design with a total of 72 participants from 5 sites across the United States. Study participants were randomized to either the Revel pump group or the t:slim Pump group. Participants were 18 years of age or older and managed their diabetes using multiple daily insulin injections. Dependent variables included training time, training satisfaction, time on task, task failures, System Usability Scale (SUS) ratings, perceived task difficulty, and a pump survey that measured different aspects of the pumps and training sessions. There was a statistically significant difference in training times and error rates between the t:slim and Revel groups. The training time difference represented a 27% reduction in time to train on the t:slim versus the Revel pump. There was a 65% reduction in participants' use error rates between the t:slim and the Revel group. The t:slim Pump had statistically significant training and usability advantages over the Revel pump. The reduction in training time may have been a result of an optimized information architecture, an intuitive navigational layout, and an easy-to-read screen. The reduction in use errors with the t:slim may have been a result of dynamic error handling and active confirmation screens, which may have prevented programming errors.

Для цитирования: Schaeffer Noel E, Parks Linda J, Verhoef Erik T, Bailey Timothy S, Schorr Alan B, Davis Trent, Halford Jean, Sulik Becky. Usability and training differences between two personal insulin pumps.. Journal of diabetes science and technology. 2014. DOI: 10.1177/1932296814555158.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.