MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2024.111540

Медицинская библиотека · Injury · 2024

Are extra locking bolts or fibular plating more important in extreme nailing of distal tibia fractures? A cadaveric biomechanical analysis.

Cunningham Daniel J, Lawrence Joshua E, Kovvur Murali, Turner Kristin E, Oppizzi Giovanni, Xu Dali, Zhang Li-Qun, Johnson Daniel J, Mittwede Peter, Sepehri Aresh, Brand Jordan, O'Toole Robert V, Gage Mark J

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

In far-distal extra-articular tibia fracture "extreme" nailing, debate surrounds the relative biomechanical performance of plating the fibula compared with extra distal interlocks. This study aimed to evaluate several constructs for extreme nailing including one interlock (one medial-lateral interlock), one interlock + plate (one medial-lateral interlock with lateral fibula compression plating), and two interlocks (one medial-lateral interlock and one anterior-posterior interlock).

METHODS

Fifteen pairs of fresh cadaver legs were instrumented with a tibial nail to the physeal scar. A 1 cm segment of bone was resected from the distal tibia 3.5 cm from the joint and an oblique osteotomy was made in the distal fibula. We loaded specimens with three different distal fixation constructs (one interlock, one interlock + plate, and two interlocks) through 10,000 cycles form 100N-700 N of axial loading. Load to failure (Newtons), angulation and displacement were also measured.

RESULTS

Mean load to failure was 2092 N (one interlock), 1917 N (one interlock + plate), and 2545 N (two interlocks). Linear mixed effects modeling demonstrated that two interlocks had a load to failure 578 N higher than one interlock alone (95 % CI, 74N-1082 N; P = 0.02), but demonstrated no significant difference between one interlock and one interlock + plate. No statistically significant difference in rates or timing of displacement >2 mm or angulation >10° were demonstrated.

CONCLUSIONS

When nailing far-distal extra-articular tibia and fibula fractures, adding a second interlock provides more stability than adding a fibular plate. Distal fibula plating may have minimal biomechanical effect in extreme nailing.

Для цитирования: Cunningham Daniel J, Lawrence Joshua E, Kovvur Murali, Turner Kristin E, Oppizzi Giovanni, Xu Dali, Zhang Li-Qun, Johnson Daniel J, Mittwede Peter, Sepehri Aresh, Brand Jordan, O'Toole Robert V, Gage Mark J. Are extra locking bolts or fibular plating more important in extreme nailing of distal tibia fractures? A cadaveric biomechanical analysis.. Injury. 2024. DOI: 10.1016/j.injury.2024.111540.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.