MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11999-011-2178-2

Медицинская библиотека · Clinical orthopaedics and related research · 2011

Does lengthening and then plating (LAP) shorten duration of external fixation?

Harbacheuski Ryhor, Fragomen Austin T, Rozbruch S Robert

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Classic bone lengthening requires patients wear external fixation for the distraction and consolidation phases and there is fracture risk after frame removal. Our technique of lengthening with the Taylor Spatial Frame(TM) and then insertion of a locked plate allows earlier removal of the external fixator during consolidation. Plate insertion is accomplished through a clean pin-free zone avoiding contamination and before frame removal maintaining bone position.

QUESTIONS/PURPOSES: We asked (1) whether lengthening and then plating (LAP) decrease the time for external fixation (2) how alignment and complications compare with those of the classic method.

METHODS

We performed a retrospective case-matched comparison between LAP and the classic technique with 27 extremities in each group. We compared time wearing the frame, bone healing index, external fixation index, joint ROM, alignment, and complications.

RESULTS

The time wearing the frame and external fixation index were lower in the LAP group (4.5 versus 6.2 months and 1.5 versus 2 months/cm). Deviation from normal alignment was observed in seven and six patients in the LAP and classic group, respectively. Varus malalignment in two patients in the LAP group was associated with plate breakage. The incidence of pin-tract infection was greater in the classic group (12 versus two). No deep infections occurred in the LAP group.

CONCLUSIONS

The LAP technique shortened the time patients wore the external fixator but was associated with a high incidence of varus deformity. Stronger plates may help prevent deformity and allow earlier removal of the frame.

LEVEL OF EVIDENCE: Level III, therapeutic study (retrospective study). See the Guidelines for Authors for a complete description of levels of evidence.

Для цитирования: Harbacheuski Ryhor, Fragomen Austin T, Rozbruch S Robert. Does lengthening and then plating (LAP) shorten duration of external fixation?. Clinical orthopaedics and related research. 2011. DOI: 10.1007/s11999-011-2178-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.