MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bsd.0b013e3181c37438

Медицинская библиотека · Journal of spinal disorders & techniques · 2010

Spinal instrumentation for sacral-pelvic fixation: a biomechanical comparison between constructs ending with either S2 bicortical, bitriangulated screws or iliac screws.

Kim Jin-Hwan, Horton William, Hamasaki Takahiko, Freedman Brett, Whitesides Thomas E, Hutton William C

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

A biomechanical study of 2 fixation techniques for lumbosacral fixation.

OBJECTIVE

To evaluate 2 techniques, one using S1 screws combined with bicortical, bitriangulated (BCBT) S2 screws, and the other using S1 screws combined with iliac screws.

SUMMARY OF BACKGROUND DATA: Common to the 2 techniques of sacral-pelvic fixation is S1 pedicle screws; the difference lies between S2 screws versus iliac screws. Iliac screws are clinically effective, yet present clinical disadvantages that S2 screws can potentially obviate, for example, wide dissection, soft tissue coverage, crossing the sacroiliac joint, and interference with bone graft harvesting. In an effort to optimize S2 fixation, we have used a BCBT S2 technique.

METHODS

Eight fresh human sacral-pelvic specimens were harvested (average age 78.7 y; bone density 0.75 g/cm2). Screws were placed bilaterally: (1) at S1: 7.5 mm diameter screws were placed bicortical; (2) at S2: 7.5 mm diameter by 60 mm long screws were placed bicortical and bitriangulated; (3) the ilium received 7.5 mm diameter by 80-mm-long screws. Sacral-pelvic constructs were assembled and biomechanical stiffness testing was performed. The stiffness in each loading mode was calculated. After the stiffness tests were completed, each BCBT S2 screw and each iliac screw were individually loaded to determine fixation strength of each type of screw.

RESULTS

There was no significant difference in stiffness between the 2 constructs, although S1 and the BCBT S2 construct tended to be stiffer in all modes. However, for the fixation strength of screws, the iliac screws loosened at loads that were significantly greater than those for BCBT S2 screws (c.f. 435.9 N with 144.7 N).

CONCLUSIONS

Iliac screws maybe the better choice in cases with poor bone quality. However, the S1-BCBT-S2 screw construct is biomechanically an appropriate alternative to the S1-iliac screw construct and it presents clinical advantages.

Для цитирования: Kim Jin-Hwan, Horton William, Hamasaki Takahiko, Freedman Brett, Whitesides Thomas E, Hutton William C. Spinal instrumentation for sacral-pelvic fixation: a biomechanical comparison between constructs ending with either S2 bicortical, bitriangulated screws or iliac screws.. Journal of spinal disorders & techniques. 2010. DOI: 10.1097/bsd.0b013e3181c37438.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.