DOI 10.1097/bsd.0b013e3181c37438
Spinal instrumentation for sacral-pelvic fixation: a biomechanical comparison between constructs ending with either S2 bicortical, bitriangulated screws or iliac screws.
Аннотация
STUDY
DESIGN
A biomechanical study of 2 fixation techniques for lumbosacral fixation.
OBJECTIVE
To evaluate 2 techniques, one using S1 screws combined with bicortical, bitriangulated (BCBT) S2 screws, and the other using S1 screws combined with iliac screws.
SUMMARY OF BACKGROUND DATA: Common to the 2 techniques of sacral-pelvic fixation is S1 pedicle screws; the difference lies between S2 screws versus iliac screws. Iliac screws are clinically effective, yet present clinical disadvantages that S2 screws can potentially obviate, for example, wide dissection, soft tissue coverage, crossing the sacroiliac joint, and interference with bone graft harvesting. In an effort to optimize S2 fixation, we have used a BCBT S2 technique.
METHODS
Eight fresh human sacral-pelvic specimens were harvested (average age 78.7 y; bone density 0.75 g/cm2). Screws were placed bilaterally: (1) at S1: 7.5 mm diameter screws were placed bicortical; (2) at S2: 7.5 mm diameter by 60 mm long screws were placed bicortical and bitriangulated; (3) the ilium received 7.5 mm diameter by 80-mm-long screws. Sacral-pelvic constructs were assembled and biomechanical stiffness testing was performed. The stiffness in each loading mode was calculated. After the stiffness tests were completed, each BCBT S2 screw and each iliac screw were individually loaded to determine fixation strength of each type of screw.
RESULTS
There was no significant difference in stiffness between the 2 constructs, although S1 and the BCBT S2 construct tended to be stiffer in all modes. However, for the fixation strength of screws, the iliac screws loosened at loads that were significantly greater than those for BCBT S2 screws (c.f. 435.9 N with 144.7 N).
CONCLUSIONS
Iliac screws maybe the better choice in cases with poor bone quality. However, the S1-BCBT-S2 screw construct is biomechanically an appropriate alternative to the S1-iliac screw construct and it presents clinical advantages.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало