MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/brs.0000000000002671

Медицинская библиотека · Spine · 2018

Reliability of Rod Lengthening, Thoracic, and Spino-Pelvic Measurements on Biplanar Stereoradiography in Patients Treated With Magnetically Controlled Growing Rods.

Obid Peter, Yiu Karen Kar Lum, Cheung Kenneth Mc, Kwan Kenny, Ruf Michael, Cheung Jason Pui Yin

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

Cross-sectional study.

OBJECTIVE

To assess the inter- and intraobserver reliability of thoracic, spino-pelvic, and rod lengthening measurements made on biplanar spinal stereoradiography (EOS imaging) in children treated with magnetically controlled growing rod (MCGR).

SUMMARY OF BACKGROUND DATA: MCGR treatment aims to gain spine length while gradually correcting the spinal deformity. Monitoring thoracic and spino-pelvic parameters is crucial for successful management. EOS imaging is widely used for diagnosis and monitoring of children with Early Onset Scoliosis. However, there is a paucity of literature on the reliability of thoracic and spino-pelvic parameters on EOS imaging in children treated with MCGR.

METHODS

Three independent reviewers independently read a random assortment of 20 whole spine posteroanterior and lateral radiographs from patients treated with MCGR. The measurements were repeated 4 weeks after the initial read. The following radiological parameters were measured: Cobb angle of the main and compensatory curves, coronal balance, coronal T1-S1 and T1-T12 length, chest width and depth at T6, pelvic inlet width, MCGR distracted lengths, global kyphosis, proximal and distal junctional angle, lordosis, sagittal balance, pelvic incidence, pelvic tilt and sacral slope. Statistical analysis was performed with paired t test and Cronbach alpha for inter- and intraobserver reliability.

RESULTS

All measurements had good or excellent intra- and interobserver reliability (α>0.8; P < 0.05), except measurements of the proximal junctional angle which showed only poor intra- and interobserver reliability for patients with an upper instrumented vertebra cranial to T4.

CONCLUSION

EOS imaging is reliable for diagnosis and monitoring of children with Early Onset Scoliosis treated with MCGR. EOS imaging is particularly excellent for assessment of MCGR lengthening. Diagnosis and interpretation of early proximal junctional kyphosis within the cervicothoracic junction should be made with caution.

LEVEL OF EVIDENCE: 3.

Для цитирования: Obid Peter, Yiu Karen Kar Lum, Cheung Kenneth Mc, Kwan Kenny, Ruf Michael, Cheung Jason Pui Yin. Reliability of Rod Lengthening, Thoracic, and Spino-Pelvic Measurements on Biplanar Stereoradiography in Patients Treated With Magnetically Controlled Growing Rods.. Spine. 2018. DOI: 10.1097/brs.0000000000002671.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.