MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijmmb.2025.101008

Медицинская библиотека · Indian journal of medical microbiology · 2025

Diagnostic accuracy of Xpert MTB/RIF Ultra for abdominal tuberculosis in a tertiary care setting in North India.

Pathak Anuj, Raveendran Reena, Kaur Oberoi Jaswinder, Wattal Chand, Arora Anil, Singla Vikas

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Abdominal tuberculosis (TB) poses diagnostic difficulties due to its vague symptoms and low bacterial load. Culture, the gold standard, is limited by a prolonged turnaround time of up to eight weeks. Xpert MTB/RIF Ultra (Xpert Ultra), a rapid, automated molecular test, can detect Mycobacterium tuberculosis and rifampicin resistance in under two hours. This study evaluated the diagnostic accuracy of Xpert Ultra for abdominal TB using both culture and a composite reference standard (CRS), and assessed its agreement in rifampicin resistance detection with phenotypic and genotypic drug susceptibility testing (DST).

METHODS

A prospective observational study was conducted from September 2019 to March 2021 at a tertiary care centre in North India. Adults with clinical and radiological features of abdominal TB were enrolled. Relevant abdominal samples were collected and tested using smear, culture (BACTEC MGIT 960), Xpert Ultra, histopathology, and clinical response. Rifampicin resistance was confirmed using MGIT 960 and GenoType MTBDRplus.

RESULTS

Of 176 eligible patients, 144 were enrolled, yielding 152 abdominal samples: lymph node aspirates (52%), biopsies (42.8%), pus/aspirates (3.3%), and ascitic/omental fluids (2%). Xpert Ultra showed 84% diagnostic accuracy against CRS and 75% against culture. Rifampicin resistance detection showed 100% concordance with both phenotypic and genotypic DST.

CONCLUSION

Xpert Ultra offers high diagnostic accuracy and excellent concordance in rifampicin resistance detection for abdominal TB. Its speed and reliability make it a valuable diagnostic tool in high-burden settings.

Для цитирования: Pathak Anuj, Raveendran Reena, Kaur Oberoi Jaswinder, Wattal Chand, Arora Anil, Singla Vikas. Diagnostic accuracy of Xpert MTB/RIF Ultra for abdominal tuberculosis in a tertiary care setting in North India.. Indian journal of medical microbiology. 2025. DOI: 10.1016/j.ijmmb.2025.101008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.