SVM-Based Optical Detection of Retinal Ganglion Cell Apoptosis.

Kulmaganbetov Mukhit, Bevan Ryan, Want Andrew, Anantrasirichai Nantheera, Achim Alin, Albon Julie, Morgan James

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Retinal ganglion cell (RGC) loss is crucial in eye diseases like glaucoma. Axon damage and dendritic degeneration precede cell death, detectable within optical coherence tomography (OCT) resolution, indicating their correlation with neuronal degeneration. The purpose of this study is to evaluate the optical changes of early retinal degeneration.

METHODS

The detection of optical changes in the axotomised retinal explants was completed in six C57BL/6J mice. OCT images were acquired up to 120 min from enucleation. A grey-level co-occurrence-based texture analysis was performed on the inner plexiform layer (IPL) to monitor changes in the optical speckles using a principal component analysis (PCA) and a support vector machine (SVM). In parallel tests, retinal transparency was confirmed by a comparison of the modulation transfer functions (MTFs) at 0 and 120 min.

RESULTS

Quantitative confirmation by analysis of the MTFs confirmed the non-degradation of optical transparency during the imaging period: MTF (fx) = 0.267 ± 0.02. Textural features in the IPL could discriminate between the optical signals of RGC degeneration. The mean accuracy of the SVM classification was 86.3%; discrimination was not enhanced by the combination of the SVM and PCA (81.9%).

CONCLUSIONS

Optical changes in the IPL can be detected using OCT following RGC axotomy. High-resolution OCT can provide an index of retinal neuronal integrity and its degeneration.

Для цитирования: Kulmaganbetov Mukhit, Bevan Ryan, Want Andrew, Anantrasirichai Nantheera, Achim Alin, Albon Julie, Morgan James. SVM-Based Optical Detection of Retinal Ganglion Cell Apoptosis.. Photonics. 2025. DOI: 10.3390/photonics12020128.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.