MedElevator Войти в исследования
← Поиск публикаций

DOI 10.52312/jdrs.2022.604

Медицинская библиотека · Joint diseases and related surgery · 2022

The evaluation of a de novo biplanar distal humerus plate: A biomechanical study.

Acar Nihat, Karakaşlı Ahmet, Gürsan Onur, Hüsemoğlu R Buğra

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study was to compare the stability of a novel biplanar distal humerus plate with the single- and double-columns J-plating techniques.

MATERIALS AND

METHODS

Eighteen sawbones humera were divided into three groups. In Groups 1, 2 and 3, biplanar plate, single lateral J-plate and double J-plate, were used, respectively. Transverse osteotomies at the upper portion of the olecranon fossa were made. Blocks of 10-mm was removed from each sample. Axial, torsional, and extensional stiffness of each group were measured.

RESULTS

The mean axial stiffness values in Groups 1, 2, and 3 were 64.80±6.75, 33.70±5.71, and 171.48±9.53 N/mm, respectively. Group 1 demonstrated a statistically significant difference compared to Group 2 (p=0.032), whereas Group 3 showed a statistically significant difference compared to Groups 1 and 2 (p=0.025 and p=0.014, respectively). The mean torsional stiffness values of Groups 1, 2, and 3 were 0.23±0.01, 0.14±0.008, and 0.30±0.007 N/ degree, respectively. Groups 1 and 3 demonstrated a statistically significant difference compared to Group 2 (p=0.042 and p=0.028, respectively). No statistically significant difference was detected between Groups 1 and 3 (p=0.27). The mean extensional bending stiffness values of Groups 1, 2 and 3 were 2.64±0.31, 1.17±0.13, and 3.2±0.1 N/mm, respectively. Group 1 demonstrated a statistically significant difference compared to Group 2 (p=0.041). There was no statistically significant difference between Groups 1 and 3 (p=0.083).

CONCLUSION

Biplanar plate allows applying enough numbers of long sagittal screws and offers more biomechanical stability than lateral column J-plate and in some aspects strong as dual J-plating in torsional and bending tests.

Для цитирования: Acar Nihat, Karakaşlı Ahmet, Gürsan Onur, Hüsemoğlu R Buğra. The evaluation of a de novo biplanar distal humerus plate: A biomechanical study.. Joint diseases and related surgery. 2022. DOI: 10.52312/jdrs.2022.604.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.