MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/spi.2006.5.2.172

Медицинская библиотека · Journal of neurosurgery. Spine · 2006

Atlantoaxial stabilization with the use of C1-3 lateral mass screw fixation. Technical note.

Horn Eric M, Hott Jonathan S, Porter Randall W, Theodore Nicholas, Papadopoulos Stephen M, Sonntag Volker K H

Клиническое исследованиеСтатьяTechnical ReportПеревод в очереди

Аннотация

Atlantoaxial stabilization has evolved from simple posterior wiring to transarticular screw fixation. In some patients, however, the course of the vertebral artery (VA) through the axis varies, and therefore transarticular screw placement is not always feasible. For these patients, the authors have developed a novel method of atlantoaxial stabilization that does not require axial screws. In this paper, they describe the use of this technique in the first 10 cases. Ten consecutive patients underwent the combined C1-3 lateral mass-sublaminar axis cable fixation technique. The mean age of the patients was 62.6 years (range 23-84 years). There were six men and four women. Eight patients were treated after traumatic atlantoaxial instability developed (four had remote trauma and previous nonunion), whereas in the other two atlantoaxial instability was caused by arthritic degeneration. All had VA anatomy unsuitable to traditional transarticular screw fixation. There were no intraoperative complications in any of the patients. Postoperative computed tomography studies demonstrated excellent screw positioning in each patient. Nine patients were treated postoperatively with the aid of a rigid cervical orthosis. The remaining patient was treated using a halo fixation device. One patient died of respiratory failure 2 months after surgery. Follow-up data (mean follow-up duration 13.1 months) were available for seven of the remaining nine patients and demonstrated a stable construct with fusion in each patient. The authors present an effective alternative method in which C1-3 lateral mass screw fixation is used to treat patients with unfavorable anatomy for atlantoaxial transarticular screw fixation. In this series of 10 patients, the method was a safe and effective way to provide stabilization in these anatomically difficult patients.

Для цитирования: Horn Eric M, Hott Jonathan S, Porter Randall W, Theodore Nicholas, Papadopoulos Stephen M, Sonntag Volker K H. Atlantoaxial stabilization with the use of C1-3 lateral mass screw fixation. Technical note.. Journal of neurosurgery. Spine. 2006. DOI: 10.3171/spi.2006.5.2.172.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.