Anatomical study of the modified direct posterior gluteal splitting approach for acetabular fractures.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Matsugaki Toru, Yamashita Akihiro, Kikuchi Keishiro, Watanabe Koichi

Аннотация

BACKGROUND: In this study, we investigated the area that can be addressed with an approach in which the skin incision is made directly above the dorsal column with Thiel cadaveric specimens.

METHODS: Six Thiel cadaveric specimens were prepared. A skin incision was made directly above the dorsal column. The accessible proximal end from the proximal part of the greater sciatic notch to the gluteal ridge and the accessible distal end of the ischium were marked with a flat chisel. A molded 8-hole reconstruction plate was placed from the base of the ischium toward the gluteal ridge and fixed with 3 screws proximally and 2 screws distally. The length of the skin incision and the distance from each reference point on the bone to the reachable markings were assessed after the muscles were removed.

RESULTS: Mean skin incision length was 9.3 ± 0.7 (range, 8.0-10.0) cm. In 3 of 6 cases, proximal screws were inserted through different spaces between muscle fibers. In all cases, we were able to reach at least the greater sciatic notch, the gluteal ridge at the level of superior border of the acetabulum, and the base of the ischial tuberosity. In all cases, an 8-hole plate could be placed from the gluteal ridge to the base of the ischium. There were no superior gluteal artery or sciatic nerve injuries in any of the cases.

CONCLUSION: We anatomically investigated the area that can be addressed with an approach in which the skin incision was made directly above the dorsal column. In all cases, we were able to access the areas needed to reduce the fracture and place the plates necessary to stabilize the fracture through a 9.3 ± 0.7 cm skin incision. This approach can be a useful minimally invasive posterior approach for acetabular fractures.