MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/2309499018783913

Медицинская библиотека · Journal of orthopaedic surgery (Hong Kong) · 2018

Midterm outcome of fourth-generation ceramic-on-ceramic bearing surfaces in revision total hip arthroplasty.

Chang Jun-Dong, Kim In-Sung, Mansukhani Sameer Ajit, Sharma Vishwas, Lee Sang-Soo, Yoo Je-Hyun

СтатьяПеревод в очереди

Аннотация

PURPOSE: The purpose of this study is to evaluate the clinical and radiologic outcomes after revision total hip arthroplasty (THA) using fourth-generation ceramic-on-ceramic (CoC) bearing surfaces.

METHODS

A total of 52 revision THAs (28 men and 19 women) using the fourth-generation CoC bearing surfaces were retrospectively evaluated. Both acetabular cup and femoral stem were revised in all cases. The mean follow-up period was 7.3 years (range, 4.0-9.9 years). The clinical results with Harris hip score (HHS), Western Ontario McMaster Osteoarthritis Index (WOMAC), and radiologic outcomes were evaluated.

RESULTS

At the final follow-up examination, the average HHS was 90.4 (range, 67-100). The average WOMAC pain and physical function score were 2.8 (range, 0-12) and 16.4 (range, 0-42), respectively. Complications were observed in 10 hips (19.2%). However, there were no bearing surface-related complications, and no cases of dislocation and squeaking. Retroacetabular pelvic osteolysis without cup loosening was observed in one hip at the final follow-up. However, no hip showed radiographic signs of cup loosening, vertical or horizontal acetabular cup migrations, and changes of inclinations during the follow-up period.

CONCLUSION

Our data showed that clinical and radiologic outcomes after revision THA using fourth-generation CoC bearing were favorable. Hence, revision THA with the use of CoC bearing surfaces can be preferentially considered. Further studies with long-term follow-up data are warranted.

Для цитирования: Chang Jun-Dong, Kim In-Sung, Mansukhani Sameer Ajit, Sharma Vishwas, Lee Sang-Soo, Yoo Je-Hyun. Midterm outcome of fourth-generation ceramic-on-ceramic bearing surfaces in revision total hip arthroplasty.. Journal of orthopaedic surgery (Hong Kong). 2018. DOI: 10.1177/2309499018783913.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.