m+Medelevator.RU
← Поиск публикаций
Frontiers in neurology · 2025

Validating wearable step counts in multiple sclerosis research: a replication study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Goldman Myla D, Chen Shanshan, Kunisetty Bhavana, Gelfand Jeffrey M, Cree Bruce A C, Block Valerie J

Аннотация

INTRODUCTION: For people with multiple sclerosis (MS), mobility impairment is common and a significant contributor to reduced quality of life. With advancements in wearable technology, step count data has emerged as a promising method to track mobility and monitor functional decline. However, studies comparing the replicability of wearable mobility data using varying devices remain limited in MS populations.

METHODS: This study investigates the reliability of step count data and its associations with clinical outcomes in MS patients using two independent cohorts with different wearable devices: California (CA) (n = 97 Fitbit wrist sensor, 4-week wear) and Virginia (VA) (n = 61; ActiGraph hip sensor, 7-day wear). We analyzed correlations between average daily step counts and common MS clinical measures [disability: Expanded Disability Status Scale (EDSS); walking speed: Timed 25-Foot Walk (T25FW)] as well as patient-reported outcomes (12-item MS walking scale, MSWS-12, Modified Fatigue Impact score, MFIS).

RESULTS: Analysis of the VA cohort revealed similar average daily step counts to those seen in the CA cohort (6,010 vs. 5,478 steps/day). Step count variability (standard deviation) decreased with increasing EDSS in both cohorts. Step counts in the VA cohort were significantly correlated with EDSS (r = -0.34), T25FW (r = -0.58), MSWS-12 (r = -0.57), and MFIS (r = -0.45), similar to findings from the CA cohort. Additionally, within-subject reliability over 7 days was moderate (ICC = 0.599), with high correlations between 4-day and 7-day averages (r ≥ 0.98).

DISCUSSION: The step count analyses from two different wearable devices show replicable associations with clinical and patient-reported outcomes in MS, highlighting their promise as digital biomarkers for clinical monitoring and care, rehabilitation, and patient self-management.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты