m+Medelevator.RU
← Поиск публикаций
Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2014

Surgical repair of thoraco-lumbar vertebral fracture-luxations in eight cats using screws and polymethylmethacrylate fixation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vallefuoco R, Manassero M, Leperlier D, Scotti S, Viateau V, Moissonnier P

Аннотация

OBJECTIVE: To report our clinical experience in the surgical treatment of feline thoraco-lumbar vertebral fracture-luxations using optimal safe implantation corridors as previously described in vitro.

STUDY DESIGN: Retrospective clinical study.

MATERIALS AND METHODS: Medical records and radiographs of cats with vertebral fracture-luxations stabilized by screws and polymethylmethacrylate (PMMA) using optimal safe implantation corridors between 2009 and 2011 were reviewed. For each patient the data included: signalment, cause of vertebral fracture-luxations, presence of concurrent injuries, pre- and postoperative neurological grade, surgical treatment, imaging findings, and clinical outcome with short-term (2 weeks) and long-term (12 months) follow-up.

RESULTS: Eight cats with vertebral fracture-luxations involving the lumbar (L)(n = 5), the thoracic (T) spinal segments (n = 2), or the thoraco-lumbar junction (n = 1) were included in the study. Screws and PMMA were used bilaterally in five cats and unilaterally in three cats. No surgical intra-operative complications using the defined corridors were recorded. Implant failure followed by spontaneous recovery was recorded in one case. Two cats died in the postoperative period (≤ 4 days). The short-term and long-term clinical outcome was excellent in four out of eight cats and satisfactory in two out of eight cats.

CONCLUSION AND CLINICAL RELEVANCE: This pilot study demonstrates the clinical applicability of optimal safe implantation corridors for stabilization of feline thoraco-lumbar vertebral fracture-luxations with screws and PMMA. This technique can be used with limited risks of iatrogenic injuries for stabilization of vertebral fracture-luxation localized between T11-L4.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты