MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7507/1002-1892.201701017

Медицинская библиотека · Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2017

[Effectiveness of acetabular revision using a metal reconstruction cage].

You Zhenjun, Sun Junying, Jiang Yi, Liu Shiliang, Wu Keqin, Li Zhe, Qin Li

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To explore the clinical outcomes of acetabular revision using a metal reconstruction cage.

METHODS

Between October 2006 and October 2013, 16 patients (16 hips) underwent acetabular revision with a metal reconstruction cage. There were 4 males and 12 females, with the mean age of 62.7 years (range, 49-78 years). The time from total hip arthroplasty to revision was 3-15 years (mean, 8.2 years). The causes for revision were aseptic acetabular loosening in 15 cases, and femoral periprosthetic fracture (Vancouver type B3) in 1 case. According to the American Academy of Orthopaedic Surgeons (AAOS) classification, there were 12 cases of type III and 4 cases of type IV; according to the Paprosky classification, there were 12 cases of type IIIA and 4 cases of type IIIB. Harris score was used for hip function evaluation, and visual analogue scale (VAS) for pain in the thigh. X-ray films were taken for imaging evaluation.

RESULTS

Healing of incision by first intention was obtained in all patients. Deep venous thrombosis occurred in 1 patient, and was cured after anticoagulation therapy. No complications of infection, neurovascular injury, and prosthetic dislocation were found. Sixteen patients were followed up 6.8 years on average (range, 2-9 years). The Harris score was significantly increased from preoperative 42.44±4.66 to 91.88±3.28 at last follow-up ( t=-106.30, P=0.00). Two patients had mild pain in the thigh, but pain disappeared at 1 year after operation. At immediate after operation, the abduction angle was 37-54° (mean, 42.9°). The distance between acetabular rotation centre and teardrop line was (33.67±12.19) mm for preoperative value and was (20.67±9.63) mm for postoperative value, showing significant difference ( t=-9.60, P=0.00). The distance between acetabular rotation centre and lateral teardrop was (34.98±12.30) mm for preoperative value and was (40.04±6.61) mm for postoperative value, showing significant difference ( t=-3.15, P=0.00). X-ray film results showed bony fusion at the osteotomy sites at 4 to 12 months after operation. No continuous radiolucent line, prosthetic dislocation, or osteolysis was found, and bony ingrowth was observed in all patients. No patient received re-revision due to prosthetic loosening.

CONCLUSION

The metal reconstruction cage for acetabular revision can achieve good effectiveness for patients with serious bone defect.

Для цитирования: You Zhenjun, Sun Junying, Jiang Yi, Liu Shiliang, Wu Keqin, Li Zhe, Qin Li. [Effectiveness of acetabular revision using a metal reconstruction cage].. Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery. 2017. DOI: 10.7507/1002-1892.201701017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.