OBJECTIVE

Investigating the clinical efficacy of treating dorsally displaced distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires.

METHODS

Retrospectively analyzed the clinical data of 15 patients with distal radial double-column Die-punch fractures treated with an external fixator combined with Kirschner wire between July 2020 and January 2023. There were 10 males and 5 females;6 cases on the left side and 9 on the right;age ranged from 22 to 76 years old. Recorded the preoperative and the final follow-up Cooney wrist function scores for the patients. The fracture healing time, and occurrence of complications were recorded.

RESULTS

All 15 patients were followed up ranged from 12 to 16 months post-operation. All fractures achieved bony union, healing time ranging form 8 to 16 weeks. Not a single patient exhibited complications such as surgical site infection, fracture redislocation, or tendon injury. All individuals had their Kirschner wires and external fixation devices removed six weeks post-operatively and commenced rehabilitative therapy for wrist articulation. The Cooney wrist function scores at preoperative and ranged from 5 to 45 scores, at the latest follow-up ranged from 65 to 100 scores. At the final follow-up, the results were assessed as excellent in 10 patients, good in 4 patients, and fair in 1 patient.

CONCLUSION

The clinical efficacy of treating distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires is satisfactory.

Для цитирования: Jiao Fu-de, Zhang Jing-Wei, Zhu Li-Mei, An Lin, Zhuang Yun-Qiang, Chen Jian-Ming. [Dorsally displaced distal radial double-column Die-punch fractures by dorsal approach external fixator combined with Kirschner wires].. Zhongguo gu shang = China journal of orthopaedics and traumatology. 2025. DOI: 10.12200/j.issn.1003-0034.20231218.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.