MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/cnm.3842

Медицинская библиотека · International journal for numerical methods in biomedical engineering · 2024

Stem to prevent periprosthetic fracture after notching in total knee arthroplasty.

Wan Qian, Zhang Aobo, Liu Yang, Chen Hao, Zhao Xue, Han Qing, Wang Jincheng

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Improper osteotomy during total knee arthroplasty (TKA) can lead to anterior femoral notching, which increases the risk of periprosthetic fractures due to stress concentration. One potential solution is the addition of an intramedullary stem to the femoral component. However, the optimal stem length remains unclear. In this study, we aimed to determine the optimal stem length using finite element models. Finite element models of femurs were developed with unstemmed prostheses and prostheses with stem lengths of 50, 75, and 100 mm. Under squat loading conditions, the von Mises stress at the notch and stress distribution on four transversal sections of the femur were analyzed. Additionally, micromotion of the prosthesis-bone interface was evaluated to assess initial stability. The unstemmed prosthesis exhibited a von Mises stress of 191.8 MPa at the notch, which decreased to 43.1, 8.8, and 23.5 MPa for stem lengths of 50, 75, and 100 mm, respectively. The stress reduction on four selected femoral transversal sections compared with the unstemmed prosthesis was 40.0%, 84.4%, and 67.1% for stem lengths of 50, 75, and 100 mm, respectively. Micromotion analysis showed a maximum of 118.8 μm for the unstemmed prosthesis, which decreased significantly with the application of stems, particularly at the anterior flange. Intramedullary stems effectively reduced stress concentration at the femoral notch. The 50-mm stem length provided the optimal combination of reduced notch stress, minimized stress-shielding effect, and decreased micromotion at the anterior flange.

Для цитирования: Wan Qian, Zhang Aobo, Liu Yang, Chen Hao, Zhao Xue, Han Qing, Wang Jincheng. Stem to prevent periprosthetic fracture after notching in total knee arthroplasty.. International journal for numerical methods in biomedical engineering. 2024. DOI: 10.1002/cnm.3842.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.