MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40634-022-00487-7

Медицинская библиотека · Journal of experimental orthopaedics · 2022

Restoration of the patient-specific anatomy of the distal fibula based on a novel three-dimensional contralateral registration method.

Calek Anna-Katharina, Hodel Sandro, Hochreiter Bettina, Viehöfer Arnd, Fucentese Sandro, Wirth Stephan, Vlachopoulos Lazaros

СтатьяПеревод в очереди

Аннотация

PURPOSE: Posttraumatic fibular malunion alters ankle joint biomechanics and may lead to pain, stiffness, and premature osteoarthritis. The accurate restoration is key for success of reconstructive surgeries. The aim of this study was to analyze the accuracy of a novel three-dimensional (3D) registration algorithm using different segments of the contralateral anatomy to restore the distal fibula.

METHODS

Triangular 3D surface models were reconstructed from computed tomographic data of 96 paired lower legs. Four segments were defined: 25% tibia, 50% tibia, 75% fibula, and 75% fibula and tibia. A surface registration algorithm was used to superimpose the mirrored contralateral model on the original model. The accuracy of distal fibula restoration was measured.

RESULTS

The median rotation error, 3D distance (Euclidean distance), and 3D angle (Euler's angle) using the distal 25% tibia segment for the registration were 0.8° (- 1.7-4.8), 2.1 mm (1.4-2.9), and 2.9° (1.9-5.4), respectively. The restoration showed the highest errors using the 75% fibula segment (rotation error 3.2° (0.1-8.3); Euclidean distance 4.2 mm (3.1-5.8); Euler's angle 5.8° (3.4-9.2)). The translation error did not differ significantly between segments.

CONCLUSION

3D registration of the contralateral tibia and fibula reliably approximated the premorbid anatomy of the distal fibula. Registration of the 25% distal tibia, including distinct anatomical landmarks of the fibular notch and malleolar colliculi, restored the anatomy with increasing accuracy, minimizing both rotational and translational errors. This new method of evaluating malreductions could reduce morbidity in patients with ankle fractures.

LEVEL OF EVIDENCE: IV.

Для цитирования: Calek Anna-Katharina, Hodel Sandro, Hochreiter Bettina, Viehöfer Arnd, Fucentese Sandro, Wirth Stephan, Vlachopoulos Lazaros. Restoration of the patient-specific anatomy of the distal fibula based on a novel three-dimensional contralateral registration method.. Journal of experimental orthopaedics. 2022. DOI: 10.1186/s40634-022-00487-7.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.