Lack of agreement between different observers and methods in the measurement of capillary refill time in healthy volunteers: an observational study.

Espinoza Emilio Daniel Valenzuela, Welsh Sebastián, Dubin Arnaldo

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Peripheral perfusion abnormalities are relevant manifestations of shock. Capillary refill time is commonly used for their evaluation. However, the reproducibility of capillary refill time measurements and their correlation with other variables of peripheral perfusion, have not been comprehensively evaluated. Our goal was to determine, in healthy volunteers, the agreement between different methods of capillary refill time quantification and different observers, as well as their correlation with other markers of peripheral perfusion.

Methods

We studied 63 healthy volunteers. Two observers measured capillary refill time by means of two methods, direct view (CRTchronome ter) and video analysis (CRTvideo). We also measured perfusion index (PI) derived from pulse plethysmography and finger pad temperature (T°peripheral). The agreement between observers and methods was assessed using the Bland and Altman method. Correlations were calculated using Pearson's correlation. A p-value<0.05 was considered significant.

RESULTS

The 95% limits of agreement between the two observers were 1.9 sec for CRTchronometer and 1.7 sec for CRTvideo. The 95% limits of agreement between CRTchronometer and CRTvideo were 1.7 sec for observer 1 and 2.3 sec for observer 2. Measurements of CRTchronometer performed by the two observers were correlated with T°peripheral. Measurements of CRTvideo performed by the two observers were correlated with T°peripheral and perfusion index.

CONCLUSION

In healthy volunteers, measurements of capillary refill time performed by either different observers or different methods showed poor agreement. Nevertheless, capillary refill time still reflected peripheral perfusion as shown by its correlation with objective variables of peripheral perfusion.

Для цитирования: Espinoza Emilio Daniel Valenzuela, Welsh Sebastián, Dubin Arnaldo. Lack of agreement between different observers and methods in the measurement of capillary refill time in healthy volunteers: an observational study.. Revista Brasileira de terapia intensiva. 2014. DOI: 10.5935/0103-507x.20140038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.