Аннотация

PURPOSE: To compare the clinical efficacy of arthroscopic TightRope loop titanium button and clavicular hook plate in the treatment of acromioclavicular joint (ACJ) dislocation of Rockwood III/IV.

METHODS

A retrospective analysis of patients with ACJ dislocation in our hospital from January 2018 to December 2020 was conducted. The patients were assigned to be treated with arthroscopic TightRope loop titanium button (TR group) or clavicular hook plate (HP group). The preoperative, intraoperative and postoperative data and imaging findings of the two groups were compared.

RESULTS

A total of 58 eligible patients were enrolled in this study. Compared with HP group, TR group had shorter incision length and less blood loss during operation. Postoperative follow-up ranged from 12 to 24 months (mean 15.4 months). At 6 months and 12months postoperatively, compared with HP group, TR group had lower VAS and higher CMS, and the difference was statistically significant. At 12 months postoperatively, compared with HP group, TR group had lower ACJ gap and coracoclavicular joint(CCJ) distance, and the difference was statistically significant.In HP group, there were 3 cases of subacromial impact, 1 case of redislocation, 2 cases of traumatic arthritis and 2 cases of wound infection. There was 1 case of redislocation in TR group.

CONCLUSIONS

Compared with clavicular hook plate, arthroscopic TightRope loop titanium button is minimally invasive, safe and effective in the treatment of ACJ dislocation, and has a good trend in clinical application.

Для цитирования: Wang Yafei, Ren Chengzhen, Niu Junqi, Cao Le, Yang Can, Bi Fanggang, Tian Ke. Surgical treatment of acromioclavicular joint dislocation of Rockwood III/IV: a retrospective study on clavicular hook plate versus arthroscopic TightRope loop titanium button.. BMC musculoskeletal disorders. 2024. DOI: 10.1186/s12891-024-07269-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.