Changes in cobalt and chromium levels after metal-on-metal hip resurfacing in young, active Chinese patients.

Yang Jing, Shen Bin, Zhou ZongKe, Pei Fuxing, Kang PengDe

СтатьяПеревод в очереди

Аннотация

Metal-on-metal resurfacing arthroplasty is increasingly being performed in young, active patients. Serum and urine metal ion levels are monitored in these patients to assess the physiologic effects of metal-on-metal wear on them. The aim of our prospective study was to evaluate the serum and urine levels of cobalt (Co) and chromium (Cr) in young (age, ≤50 years), active Chinese patients who had undergone metal-on-metal hybrid resurfacing arthroplasties. Levels were measured preoperatively using atomic absorption spectrometry and then sequentially at 3, 6, 9, 12, and 24 months after surgery. For both serum and urine Co and Cr, there was an initial increase to a peak at 6 months, followed by a gradual decline after 6 months, whereas renal function was normal during the study the 2-year study period. There was no radiographic evidence of component loosening. All implants were functioning well. Further long-term studies are needed to observe clinical outcomes and to determine the physiologic effects of the wearing process.

Для цитирования: Yang Jing, Shen Bin, Zhou ZongKe, Pei Fuxing, Kang PengDe. Changes in cobalt and chromium levels after metal-on-metal hip resurfacing in young, active Chinese patients.. The Journal of arthroplasty. 2010. DOI: 10.1016/j.arth.2009.11.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.