Effect of Blood Decontamination Procedures on the Microshear Bond Strength of Resin-modified Glass Ionomer Cement to Resin Composite.
Аннотация
OBJECTIVE
To investigate the effect of decontamination procedures on the microshear bond strength (μSBS) of blood-contaminated resin-modified glass ionomer cement (RMGIC) bonded to resin composite (RC).
METHODS
Eighty RMGIC disc specimens were allocated into 5 groups (n=16). All groups except Group 2 were contaminated with blood. Group 1 had no decontamination procedure, Group 3 was decontaminated by rinsing, Group 4 was decontaminated by 34% phosphoric acid etching, and Group 5 was decontaminated by 5% sodium hypochlorite application. RMGIC specimens were subsequently bonded with RC using a universal adhesive in self-etch mode. μSBS tests were conducted using a universal testing machine at a crosshead speed of 1 mm/min. Failure mode analysis was conducted on RMGIC fracture surfaces under a scanning electron microscope.
RESULTS
μSBS results indicated that Group 4 had the highest mean μSBS value of 6.22 ± 2.14 MPa, while Group 1 had the lowest mean μSBS value of 3.53 ±1.67 MPa. Significant differences were observed in the μSBS of Group 2 with no contamination (p=0.023) and Group 4 with decontamination by phosphoric acid-etching (p=0.003) when compared to Group 1 with blood contamination. No statistically significant differences (p>0.05) were observed between all other groups' μSBS. For all groups, the predominant mode of failure was adhesive failure between the RMGIC-RC interface, with a few mixed failures in RMGIC for Groups 2-5.
CONCLUSIONS
Blood contamination before adhesive application significantly reduced the μSBS between RMGIC and RC. Phosphoric acid etching was the most effective blood decontamination procedure to improve the μSBS.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.