STATEMENT OF PROBLEM: The impact of various preparation designs on the fracture resistance and fracture type of mandibular premolars restored with 3 dimensionally (3D) printed, 1-piece endodontic crowns remains unclear.

PURPOSE: The purpose of this study was to investigate the effect of different preparation designs on the fracture resistance and fracture patterns of mandibular premolars restored with 3D printed 1-piece endodontic crowns after thermal aging.

MATERIAL AND

METHODS

Forty-five freshly extracted mandibular premolars received 3 different preparation designs: with at least 2 intact cuspal walls (2CW), with only 1 intact cuspal wall (1CW), and no cuspal wall present (NoCW). One-piece endodontic crowns were designed by using a computer-aided design (CAD) software program, 3D printed, cemented to the prepared teeth with self-adhesive resin cement, and thermocycled between 5 °C and 55 °C in artificial saliva. Subsequently, all specimens were subjected to a fracture test. The results were statistically analyzed using 1-way ANOVA (α=.05), and fracture types of all specimens were examined using a light microscope.

RESULTS

The analysis of fracture resistance values across separate designs revealed no statistically significant differences (P>.05). Mean fracture resistance values were 724.5 N in 2CW, 713 N in 1CW, and 861 N in NoCW. In 2CW and 1CW, the 1-piece endodontic crowns mostly displayed Type III fractures, whereas those in NoCW exhibited a combination of Type II and Type III fractures.

CONCLUSIONS

The mandibular premolar 1-piece endodontic crowns tested in this study exhibited similar fracture resistance and type of fracture with different preparation designs.

Для цитирования: Bahadır Hasibe Sevilay, Bulut Ali Can, Yılmaz Burak. Effect of preparation design on the fracture resistance and fracture patterns of 3D printed one-piece endodontic crowns.. The Journal of prosthetic dentistry. 2024. DOI: 10.1016/j.prosdent.2024.06.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.