MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/rheumatology/kev112

Медицинская библиотека · Rheumatology (Oxford, England) · 2015

International Consensus for ultrasound lesions in gout: results of Delphi process and web-reliability exercise.

Gutierrez Marwin, Schmidt Wolfgang A, Thiele Ralf G, Keen Helen I, Kaeley Gurjit S, Naredo Esperanza, Iagnocco Annamaria, Bruyn George A, Balint Peter V, Filippucci Emilio, Mandl Peter, Kane David, Pineda Carlos, Delle Sedie Andrea, Hammer Hilde Berner, Christensen Robin, D'Agostino Maria Antonietta, Terslev Lene, OMERACT Ultrasound Gout Task Force group

Сравнительное исследованиеConsensus StatementСтатьяПоддержка исследования: вне правительства СШАСистематический обзорВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To produce consensus-based definitions of the US elementary lesions in gout and to test their reliability in a web-based exercise.

METHODS

The process consisted of two steps. In the first step a written Delphi questionnaire was developed from a systematic literature review and expert international consensus. This collated information resulted in four statements defining US elementary lesions: double contour (DC), tophus, aggregates and erosion. The Delphi questionnaire was sent to 35 rheumatology experts in US, asking them to rate their level of agreement or disagreement with each statement. The second step tested the reliability by a web-exercise. US images of both normal and gouty elementary lesions were collected by the participants. A facilitator then constructed an electronic database of 110 images. The database was sent to the participants, who evaluated the presence/absence of US elementary lesions. A group of 20 images was displayed twice to evaluate intra-reader reliability.

RESULTS

A total of 32 participants responded to the questionnaires. Good agreement (>80%) was obtained for US definitions on DC, tophus, aggregates and erosion in the Delphi exercise after three rounds. The reliability on images showed inter-reader κ values for DC, tophus, aggregates, erosion findings of 0.98, 0.71, 0.54 and 0.85, respectively. The mean intra-reader κ values were also acceptable: 0.93, 0.78, 0.65 and 0.78, respectively.

CONCLUSION

This, the first consensus-based US definition of elementary lesions in gout, demonstrated good reliability overall. It constitutes an essential step in developing a core outcome measurement that permits a higher degree of homogeneity and comparability between multicentre studies.

Для цитирования: Gutierrez Marwin, Schmidt Wolfgang A, Thiele Ralf G, Keen Helen I, Kaeley Gurjit S, Naredo Esperanza, Iagnocco Annamaria, Bruyn George A, Balint Peter V, Filippucci Emilio, Mandl Peter, Kane David, Pineda Carlos, Delle Sedie Andrea, Hammer Hilde Berner, Christensen Robin, D'Agostino Maria Antonietta, Terslev Lene, OMERACT Ultrasound Gout Task Force group. International Consensus for ultrasound lesions in gout: results of Delphi process and web-reliability exercise.. Rheumatology (Oxford, England). 2015. DOI: 10.1093/rheumatology/kev112.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.