DOI 10.1097/01.brs.0000261490.90956.2b
Mechanical comparison of posterior instrumentation constructs for spinal fixation across the cervicothoracic junction.
Аннотация
STUDY
DESIGN
A biomechanical study comparing 4 different posterior implant configurations for instrumentation across the cervicothoracic junction.
OBJECTIVE
To compare mechanical parameters during flexion bending and axial rotation testing among 4 different posterior cervicothoracic rod-and-screw constructs.
SUMMARY OF BACKGROUND DATA: Several posterior rod constructs are available for instrumentation across the cervicothoracic junction. No studies have examined the mechanical properties of constructs of varying rod diameters and rod connector types.
METHODS
Four different rod-and-screw-based constructs for posterior cervicothoracic instrumentation underwent flexion bending or axial rotation testing. Stiffness, ultimate and yield forces (torques) were compared using an analysis of variance.
RESULTS
Significantly lower stiffness, ultimate and yield force (torque) was observed with a 3.5-mm rod construct compared with the 3 other constructs. No significant differences were demonstrated between a dual diameter rod (3.5 mm to 5.5 mm) and a solid domino connector extending between 3.5-mm and 5.5-mm rods. A hinged domino connector construct between 3.5-mm and 5.5-mm rods had similar stiffness but lower ultimate and yield force from either the dual diameter rod or the solid domino construct.
CONCLUSIONS
The present results demonstrate that the 3.5-mm rod-and-screw construct is the weakest configuration for posterior fixation across the cervicothoracic junction. The dual diameter rod and fixed domino connector constructs were the strongest and demonstrated similar values for yield and ultimate force.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.