MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archinte.161.2.228

Медицинская библиотека · Archives of internal medicine · 2001

Routine measurement of pleural fluid amylase is not indicated.

Branca P, Rodriguez R M, Rogers J T, Ayo D S, Moyers J P, Light R W

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

BACKGROUND

The routine measurement of pleural fluid amylase is frequently recommended, but the cost-effectiveness of this procedure is unknown.

METHODS

To assess the utility of routine measurement of pleural fluid amylase in evaluating pleural effusions, we measured amylase, glucose, lactate dehydrogenase, and protein levels and blood cell counts in 379 patients undergoing thoracentesis during a 22-month period from 1997 to 1999. Of these, 199 had effusions after cardiac surgery; 61, malignant; 48, transudative; 28, parapneumonic; 2, chylous; 2, rheumatoid; 1, tuberculous; and 1, from chronic pleuritis. There were 37 exudates of unknown origin.

RESULTS

Measurement of pleural fluid amylase levels did not assist in determining the origin of the effusion in any of the patients. Amylase levels greater than 100 U/L (normal serum level in our laboratory is 30-110 U/L) were found in 5 (1.3%) of 379 patients: 1 patient with congestive heart failure (amylase, 173 U/L), 2 with post-cardiac surgery effusions (144 U/L and 130 U/L), 1 with pneumonia (109 U/L), and 1 with lung cancer (105 U/L).

CONCLUSIONS

The routine measurement of pleural fluid amylase levels is neither clinically indicated nor cost-effective. We suggest that pleural fluid serum amylase levels be measured only if there is a pretest suspicion of acute pancreatitis, chronic pancreatic disease, or esophageal rupture.

Для цитирования: Branca P, Rodriguez R M, Rogers J T, Ayo D S, Moyers J P, Light R W. Routine measurement of pleural fluid amylase is not indicated.. Archives of internal medicine. 2001. DOI: 10.1001/archinte.161.2.228.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.