BACKGROUND

This study evaluated (1) survivorship, (2) clinical outcomes, (3) complications, and (4) radiographic outcomes of dual mobility (DM) systems when compared to fixed-bearing prostheses in revision total hip arthroplasty (THA).

METHODS

A cohort of 85 patients who underwent revision THA using DM implants were compared to a prior matching cohort of 170 patients who received fixed-bearing implants. Mean follow-up time was 4 years in the DM cohort and 10 years in the fixed-bearing cohort. Kaplan-Meier analysis was performed to assess survivorships. Clinical outcomes were evaluated using the Harris Hip Score (HHS). Complications and radiographs were evaluated and reported at the final follow-up.

RESULTS

Overall aseptic and all-cause survivorships of the DM cohort were 96.5% and 95.3% compared to 94.7% and 93.5% in fixed-bearing cohort (P = .01 for aseptic and all-cause survivorships). The DM cohort had statistically significant higher survivorship when compared at equivalent follow-up interval in the fixed-bearing cohort. There were 3 aseptic (one due to dislocation) and 1 septic revision in the DM cohort compared to 9 aseptic (6 due to dislocation) and 2 septic revisions in the fixed-bearing cohort. Postoperative HHS scores were 88 and 86 points in the DM and fixed-bearing cohorts. However, the difference in mean improvement in HHS scores from preoperative to postoperative (ΔHHS) was not statistically significant (35 vs 34, P = .533). Except for the aforementioned revisions, there were no progressive radiolucencies or osteolysis on radiographic evaluation in both cohorts.

CONCLUSION

DM articulations demonstrated superior survivorship at equal follow-up intervals when compared to fixed-bearing implants and showed a trend toward lower dislocation rates.

Для цитирования: Harwin Steven F, Sultan Assem A, Khlopas Anton, Chughtai Morad, Sodhi Nipun, Piuzzi Nicolas S, Mont Michael A. Mid-Term Outcomes of Dual Mobility Acetabular Cups for Revision Total Hip Arthroplasty.. The Journal of arthroplasty. 2017. DOI: 10.1016/j.arth.2017.12.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.