MedElevator Войти в исследования
← Поиск публикаций

DOI 10.19723/j.issn.1671-167x.2024.01.010

Медицинская библиотека · Beijing da xue xue bao. Yi xue ban = Journal of Peking University. Health sciences · 2024

[Mandibular condyle localization in orthognathic surgery based on mandibular movement trajectory and its preliminary accuracy verification].

Xu Xinyu, Wu Ling, Song Fengqi, Li Zili, Zhang Yi, Liu Xiaojing

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To establish and assess the precision of pre-surgical condyle position planning using mandibular movement trajectory data for orthognathic surgery.

METHODS

Skull data from large-field cone beam computed tomography (CBCT) and dental oral scan data were imported into IVSPlan 1.0.25 software for 3D reconstruction and fusion, creating 3D models of the maxilla and mandible. Trajectory data of mandibular movement were collected using a mandibular motion recorder, and the data were integrated with the jaw models within the software. Subsequently, three-dimensional trajectories of the condyle were obtained through matrix transformations, rendering them visually accessible. A senior oral and maxillofacial surgeon with experience in both diagnosis and treatment of temporomandibular joint disease and orthognathic surgery selected the appropriate condyle position using the condyle movement trajectory interface. During surgical design, the mobile mandibular proximal segment was positioned accordingly. Routine orthognathic surgical planning was completed by determining the location of the mandibular distal segment, which was based on occlusal relationships with maxilla and facial aesthetics. A virtual mandible model was created by integrating data from the proximal and distal segment bone. Subsequently, a solid model was generated through rapid prototyping. The titanium plate was pre-shaped on the mandibular model, and the screw hole positions were determined to design a condylar positioning guide device. In accordance with the surgical plan, orthognathic surgery was performed, involving mandibular bilateral sagittal split ramus osteotomy (SSRO). The distal segment of the mandible was correctly aligned intermaxillary, while the proximal bone segment was positioned using the condylar positioning guide device and the pre-shaped titanium plate. The accuracy of this procedure was assessed in a study involving 10 patients with skeletal class Ⅱ malocclusion. Preoperative condyle location planning and intraoperative positioning were executed using the aforementioned techniques. CBCT data were collected both before the surgery and 2 weeks after the procedure, and the root mean square (RMS) distance between the preope-rative design position and the actual postoperative condyle position was analyzed.

RESULTS

The RMS of the condyle surface distance measured was (1.59±0.36) mm (95%CI: 1.35-1.70 mm). This value was found to be significantly less than 2 mm threshold recommended by the expert consensus (P < 0.05).

CONCLUSION

The mandibular trajectory may play a guiding role in determining the position of the mandibular proximal segment including the condyle in the orthognathic surgery. Through the use of a condylar positioning guide device and pre-shaped titanium plates, the condyle positioning can be personalized and customized with clinically acceptable accuracy.

Для цитирования: Xu Xinyu, Wu Ling, Song Fengqi, Li Zili, Zhang Yi, Liu Xiaojing. [Mandibular condyle localization in orthognathic surgery based on mandibular movement trajectory and its preliminary accuracy verification].. Beijing da xue xue bao. Yi xue ban = Journal of Peking University. Health sciences. 2024. DOI: 10.19723/j.issn.1671-167x.2024.01.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.