MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/bmte.2003.48.12.339

Медицинская библиотека · Biomedizinische Technik. Biomedical engineering · 2003

[Useability of an image based nagivation system in reconstruction of leg alignment in total knee arthroplasty - results of a propsective study].

Perlick L, Bäthis H, Tingart M, Kalteis Th, Grifka J

Клиническое исследованиеКонтролируемое клиническое исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

Accurate leg alignment is one important factor for long term survival in total knee arthroplasty (TKA). The aim of this study was to determine the accuracy of a CT-based navigation system in restoration of the leg axis. 80 TKA (P.F.C.-Sigma--DePuy) were implanted either using a CT-based navigation-system or the conventional technique. There were no significant differences between the groups according to the preoperative leg deformity. Accuracy of implantation was determined on postoperative long-leg coronal and lateral x-rays. A postoperative leg axis between 3 degrees varus and 3 degrees valgus was obtained in 35/40 patients (88%) in the computer assisted and 28/40 patients (70%) in the conventional operated group. A higher precision in the sagittal plane was seen for the tibial (computer assisted: 3.9 +/- 2.2 vs. conventional TKA 1.3 +/- 5.8) and the femoral component (computer assisted: 3.5 +/- 2.3 vs. conventional TKA 6.9 +/- 3.6). The use of the CT-based VectorVision-System allows a significant improvement in the accuracy of implantation in TKA. The CT-based module has the advantage of a precise preoperative planning and a useful documentation and control tool for each important step. On the other hand there are additional costs and time consuming logistics.

Для цитирования: Perlick L, Bäthis H, Tingart M, Kalteis Th, Grifka J. [Useability of an image based nagivation system in reconstruction of leg alignment in total knee arthroplasty - results of a propsective study].. Biomedizinische Technik. Biomedical engineering. 2003. DOI: 10.1515/bmte.2003.48.12.339.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.